FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it must
be withdrawn from use immediately. Measures must be taken to prevent any accidental
restarting of the device. The safety of the device may be compromised, if, for example:
Malfunctions occur.
The housing of the device shows damage.
The device has been exposed to excessive loads.
The device has been stored improperly
Markings or labels on the device are illegible.
We recommend that a device displaying errors or in which an error is suspected be sent back
to i.safe MOBILE GmbH to be checked.
MAXIMUM OUTPUT POWER
Frequency bands Maximum output power
4G
22.9 dBm
5G
24.09 dBm
BT
9.25 dBm
BLE
8.82 dBm
2.4G
16.98 dBm
5G
15.81 dBm
5.8G
12.69 dBm
NFC
-16.678 dBuA/m at 10 m
SAR
The SAR limit of Europe is 2.0 W/kg for the body at 5 mm. The SAR limit of Europe is 4.0 W/kg
for the limbs at 0 mm. The device has been tested against this SAR limit. The highest SAR value
reported under this standard during product certification for limbs is 1.49 W/kg. The highest
SAR value reported under this standard during product certification for body is 0.7 W/kg. This
device was tested for typical body worn operations with the back of the handset kept 5 mm
from the body. The device complies with RF specifications when used at 5 mm from the body.
Belt clips, holsters and similar accessories used should not contain metallic components in the
assembly. The use of accessories that do not satisfy these requirements may not comply with
RF exposure requirements, and should be avoided.