COMMON PROBLEMS AND TROUBLESHOOTING
Common
faults
Analysis and
treatment
method:
Common
faults
Analysis and
treatment
method:
Common
faults
Analysis and
treatment
method:
The ice is blocked in the ice hopper in the dry ice box.
●
Stop the operation, open the cover, and check if there is exces-
sive dry ice filled. If so, remove some dry ice, and then contin-
ue the operation.
●
Check whether the vibration pump works. If not, contact the
manufacturer for replacement.
●
When filling dry ice into the funnel, it instantly removes the air
inside the funnel and forms condensation blocks. It requires
manual assistance using a steel rod at the center of the funnel
to fill the dry ice.
The dry ice pipe is vented but does not discharge ice
(internal ice blockage).
●
During the operation, intermittent use or intermittent shutdown
can cause the residual dry ice and compressed air mixed in
the ice outlet pipe, leading to icing. If this situation occurs: first
adjust the ice output to 0, then turn on the spray gun switch and
keep it running continuously for 3 minutes, then adjust the ice
output to 20%-30%, and then observe the ice output effect.
The dry ice pipe leaks ice and air.
●
Check the air source to ensure that the compressed air
supplied to the dry ice blaster is free of oil and water.
●
The dry ice pipe has been used for a long time, and the dry ice
has been rubbing against the pipe wall for a long time, resulting
in the internal thinning. Contact the manufacturer for replace-
ment.