Alarm
description
Fast Charging Mode, the battery type must be chosen to
output different charging voltages and currents.
In vehicle display mode, the charging voltage can be set within
the range of 10.8V to 16.0V. During standby, a small current
float charge is applied to the battery. When detecting battery
discharge, the system can output a maximum current of 40A to
maintain the battery in a fully charged state. If the set voltage
is lower than the battery voltage, the system will automatically
set the charging voltage to: battery voltage + 2V.
Forced Start Mode:
●
For batteries that have been stored for a long time and have
insufficient battery level, making it impossible to start the
vehicle and causing severe discharge or damage to the
battery, this mode can be selected. In Forced Start Mode, the
device can provide a maximum current of 400A to directly
support the instantaneous current required to start the vehicle.
●
Battery Not Connected Prompt: If the battery clamps are
properly connected and the battery voltage is above 10.8V, but
the system still displays a "Battery Not Connected" prompt, it is
recommended to first remove the battery clamps, clean the
battery terminals, and then reconnect them. If the issue
persists and the system still indicates that the battery is not
connected, please disconnect the power and contact our
after-sales service for further assistance.
●
Temperature Abnormality Prompt: If a "Temperature Abnor-
mality" prompt appears, first remove the battery clamps
without turning off the device's power switch. Allow the built-in
fan to cool the system. After a short period, when the tempera-
ture lowers, the system will automatically cancel the alarm and
return to the normal interface. If the "Temperature Abnormali-
ty" prompt appears immediately after powering on, even when
the device is not hot, do not continue using the device. Please
contact our after-sales service for assistance.
Battery Not Connected
11