AUDIO
GENERATOR
ES RX-603
L-CH
AC VIVM
o: sol
Fa
Rey
MAIN
AMP
PCB
TOP
VIEW
APPLY
1000Hz
(SINE
WAVE)
SIGNAL
TO AUX
JACK.
RY 701
ROTATE
AND
SET
VOLUME
CONTROL TO OBTAIN 21 VOLTS
lO]
lo
READING ON AC VTVM.
ADJUST
POTENTIOMETER
VR603
VR603
VR604
(VR604
FOR
R-CH ) SO THAT
À
OVERLOAD
PROTECTION
RELAY
IS
JUST
DISENGAGED.
Fig. 2.
Overload Protection Level Adjustment
Abb. 2. Uberlastungsschutzpegel-Einstellung
Fig. 2.
Réglage du niveau de protection contre la surcharge
AM Alignment Procedure
Instruments:
AM Signal Generator and AC VTVM.
Notes:
Set Function Selector switch to AM.
Input signal must be kept as low as possible to avoid AGC action.
©
Generator
°
Tuning Dial
Output Indicator
Adius
Adiust-for
Pin No. 23 (on
455kHz (400Hz
| Non interfering
AC VTVM
to
1204 and L203
Maximum
IF board)
30% mod.)
at low end of
TAPE OUT jack. | (on IF board)
reading on
through a 0.01
scale.
AC VTVM.
mfd capacitor.
1400kHz (400
1400kHz
CT5 (OSC) and
Hz 30% mod.)
CT4 (ANT) Trim
(on Front-end)
Repeat steps 2 and 3 until no further improvement is noticed.