Packaging materials must be disposed of according
to their labelling in accordance with municipal
guidelines. Further information can be found at
www.metabo.com in the "Service" section.
Only for EU countries: never dispose of
power tools in your household waste!
According to European Directive 2012/19/EU
on Waste from Electric and Electronic Equipment
and implementation in national law, used power
tools must be collected separately and recycled in
an environmentally-friendly manner.
15. Technical Specifications
Explanatory notes regarding the specifications on
page 4. Subject to change in accordance with
technical progress.
Ø
= max. diameter of the accessory
t
= max. permitted thickness of clamping
max,1
shank on accessory when using
clamping nut (10)
M
= Spindle thread
l
= Length of the sanding spindle
n
*
= No-load speed (maximum speed)
0
P
= Rated input power
1
P
= Power output
2
m
= Weight without mains cable
Measured values determined in conformity with
EN 62841.
Machine in protection class II
~
AC power
* Energy-rich, high-frequency interference can
cause fluctuations in speed. The fluctuations
disappear, however, as soon as the interference
fades away.
The technical specifications quoted are subject to
tolerances (in compliance with relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. The actual load may be higher
or lower depending on operating conditions, the
condition of the power tool or the accessories used.
Please allow for breaks and periods when the load
is lower for assessment purposes. Arrange
protective measures for the user, such as
organisational measures based on the adjusted
estimates.
Vibration total value (vector sum of three directions)
determined in accordance with EN 62841:
a
= Vibration emission value
h, S
(grinding)
K
= Uncertainty (vibration)
h,...
Typical A-effective perceived sound levels:
L
= Sound-pressure level
pa
L
= Acoustic power level
WA
K
, K
= Uncertainty
pA
WA
The noise level can exceed 80 dB(A) during
operation.
Wear ear protectors!
ENGLISH en
17