Herunterladen Diese Seite drucken

TDK relyon plasma piezo brush PZ3 handheld device Betriebsanleitung Seite 16

Vorschau ausblenden Andere Handbücher für relyon plasma piezo brush PZ3 handheld device:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
7.2
Installation
Make sure that a module is inserted in the device.
Make sure that the air inlet and nozzle outlet are not covered so that a sufficient flow of
ambient air can be drawn in by the unit.
Hold the unit only in the area of the button (picture 4), not in the area in front of it
(picture 3).
If the unit is to be mounted stationary, please observe the instructions below regarding
electrically conductive objects (picture 5 to 8).
Ensure that the ventilation / extraction of the working area is sufficient.
Press the Start/Stop button to generate plasma
The device stops plasma activation after 5 minutes at the latest and goes into standby
mode (in the case of special modules, plasma activation can stop after a shorter period of
time).
You can return to the active mode by simply pressing the Start/Stop button and restart the
activation by pressing the Start/Stop button again.
Do not reach into the work area during plasma generation. This can disturb the plasma
discharge and can also cause skin irritation or be perceived as slightly painful.
The device can be used in any spatial direction
16
3
4
BA-PZ3_ML / F0354402

Werbung

loading

Verwandte Produkte für TDK relyon plasma piezo brush PZ3 handheld device

Diese Anleitung auch für:

Relyon plasma piezo brush pz3 professional set