Setting the temperature control
Key functions
① Unlock key: Press and hold for two seconds to unlock the appliance.
② Light/CF key: Press briefly to turn the light on or off. Press and hold to switch
between Fahrenheit and Celsius.
③ Plus key: Increase the temperature.
④ Minus key: Decrease the temperature.
Automatic locking function: If there is no operation on any key for 20 seconds, the
keys will be locked automatically. Once locked, the plus and minus keys cannot be
used. However, the unlock and light/CF keys will function as normal.
- Auto light off function: If there is no operation on any key for 10 minutes, the lamp
will automatically turn off.
- Adjustable temperature range: The minimum temperature setting is 5°C/41°F. The
maximum temperature setting is 18°C / 64°F.
- Display range: The temperature display on the control panel can show a range
from 0-37°C/32-99°F.
Temperature display
- When using Celsius: If the measured temperature is within 1°C of the set
temperature, the display will show the set value. For example. if the set
temperature is 25°C, the display will show 25°C, even if the measured temperature
is between 24-26°C.
- When using Fahrenheit: If the measured temperature is within 2°F of the set
temperature, the display will show the set value. For example, if the set
temperature is 35°F, the display will show 35°F, even if the measured temperature
is between 33-37°F.
- Error code 'LL': When the measured temperature falls below 0°C, the display will
flash 'LL'. The cooling function will be stopped.
- If the temperature probe is short-circuited or disconnected, the display will show
the set temperature value. During this time, the compressor will operate for 15
minutes and then stop for 18 minutes.
- If the temperature measured by the temperature probe exceeds 37°C, the display
will show the set temperature value. In this case, the compressor will work for 15
minutes and then stop for 19 minutes.
- Forced defrosting function: After the compressor has been operating for 12 hours,
it will automatically stop working for 40 minutes to allow for defrosting.
- Memory function: Whenever the power is turned off and back on, the control board
will retain the previously set temperature value and the selected
Fahrenheit/Celsius state. The length of the power-off time does not affect the
memory function.
OPERATING YOUR UNIT
3