Operation
Communication with central controller
(1) After the controller receives the command from the centralized controller. It displays the
icon
. At this time,all the keys except the ON/OFF, fan speed, setting temperature are
invalid.
(2) After the controller receives the lock command, it displays the icon
. At this time, all
keys are invalid.
(3) In central or lock state, backlight is valid, press any keys to wake up screen.
Temperature compensation
(1) This function is used to compensate for ambient temperature. In the state of off, and the
backlight is lit up, long press FAN key for 10 seconds to enter temperature compensation in-
terface. You can adjust the parameters with
or
key. After adjustment, you need to
press MODE key to confirm change.
(2) When it is Celsius, the range of parameter adjustment is -4℃ ~ 4℃ . When it is Fahren-
heit, the range of parameter adjustment is -8 ℉ ~ 8 ℉ .
(3) This function is valid only during collecting ambient temperature of wired controller.