TROUBLE SHOOTING
Error
1. Green and yellow
LEDs flash
together for
10 minutes
2. Green – Yellow
– Red LEDs light
up together
3. Green – Yellow
– Red LEDs light
up one by one
4. RED LED is on
and no response
after connecting
well
5. Blue light
"10%" and five
lights flash
alternatively
6. Blue light
"25%" and five
lights flash
alternatively
7. Blue light
"50%" and five
lights flash
alternatively
8. Blue light
"75%" and five
lights flash
alternatively
Reason
Three times
continuous using
within three
minutes.
Clamps incorrect
attached.
Using Battery level
is too low to jump
start.
Connected battery
is below 2V or
above 12.6V.
The temperature is
lower than –25°C
The internal circuit
is broken
The unit
temperature is
below 10°C or
higher than 45°C.
Timeout for
charging
81
Solution
Please wait for
10 minutes and try
again to allow the
unit to cool down.
Reverse
the battery
connections.
Please recharge
before use.
1) Make sure your
car battery is
12V.
2) Charge your car
battery.
3) Remove all the
loads (eg: heater,
air conditioner,
light etc) and try
again.
Bring the unit to a
warm environment
Send the unit to
the professional
place for repair
The booster can
only be charged
between 10°C and
45°C.
The battery
possibly goes bad
and do not advise
customer to use
again

Werbung