SCD-xxx-E00-00 Room climate sensor
Installation Instructions
EN
DE
Application
Room sensor for recording indoor climate (Temperature +
CO2 + optional relative humidity). The maintenance-free
sensor creates the conditions for a pleasant indoor climate
and well-being. Typical applications are schools, office
buildings, hotels, cinemas or similar.
Security Advice
The installation and assembly of electrical equipment should only be performed by authorized
personnel.
The product should only be used for the intended application. Unauthorised modifications are
prohibited! The product must not be used in relation with any equipment that in case of a failure may
threaten, directly or indirectly, human health or life or result in danger to human beings, animals or
assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
Please comply with
Local laws, health & safety regulations, technical standards and regulations
Condition of the device at the time of installation, to ensure safe installation
This data sheet and installation manual
Notes on Disposal
As a component of a large-scale fixed installation, JCI products are intended to be used permanently
as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical
and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable
materials that should be recycled and not disposed of as domestic waste. Please note the relevant
regulations for local disposal.
EU conformity
Johnson Controls, Inc., declares that these products are in compliance with the essential
requirements and other relevant provisions of the EMC Directive and Rohs Directive.
SCD-xxx-E00-00 Room climate sensor
1
Issued 05.10.2020 | Rev.1

Werbung

loading

Inhaltszusammenfassung für Johnson Controls SCD E00-00 Serie

  • Seite 1 Please note the relevant regulations for local disposal. EU conformity Johnson Controls, Inc., declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive and Rohs Directive. SCD-xxx-E00-00 Room climate sensor...
  • Seite 2 Build-up of Self-Heating by Electrical Dissipative Power Temperature sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air. The dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power has to be considered when measuring temperature. In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value.
  • Seite 3 Technical Specifications Model SCD-200-E00-00 active, 2x 0..10V, CO2 + temperature SCD-201-E00-00 active, 2x 0..10V, CO2 + temperature + LCD SCD-310-E00-00 active, 3x 0..10V, CO2 + temperature + relative humidity SCD-311-E00-00 active, 3x 0..10V, CO2 + temperature + relative humidity + LCD SCD-220-E00-00 active, 2x 4..20mA, CO2 + temperature SCD-221-E00-00...
  • Seite 4 Dimensions (mm) SCD-200-E00-00 | SCD-310-E00-00 | SCD-220-E00-00 SCD-201-E00-00 | SCD-311-E00-00 | SCD-221-E00-00 SCD-xxx-E00-00 Room climate sensor...
  • Seite 5 Hausmüll entsorgt, sondern einem geordneten Recycling zugeführt werden. Die örtlich gültige Entsorgungsregelung ist zu beachten. EU Konformität Johnson Controls, Inc. erklärt, dass diese Produkte mit den wesentlichen Anforderungen und anderen relevanten Bestimmungen der EMV-Richtlinie und der Rohs-Richtlinie übereinstimmen. SCD-xxx-E00-00 Raumklimafühler...
  • Seite 6 Wärmeentwicklung durch elektrische Verlustleistung Temperaturfühler mit elektronischen Bauelementen besitzen immer eine elektrische Verlustleistung, die die Temperaturmessung der Umgebungsluft beeinflusst. Die auftretende Verlustleistung in aktiven Temperaturfühlern steigt mit der steigenden Betriebsspannung. Diese Verlustleistung muss bei der Temperaturmessung berücksichtigt werden. Bei einer festen Betriebsspannung (±0,2 V) geschieht dies in der Regel durch Addieren bzw.
  • Seite 7 Technische Daten Modelle SCD-200-E00-00 aktiv, 2x 0..10V, CO2 + Temperatur SCD-201-E00-00 aktiv, 2x 0..10V, CO2 + Temperatur + LCD SCD-310-E00-00 aktiv, 3x 0..10V, CO2 + Temperatur + relative Feuchte SCD-311-E00-00 aktiv, 3x 0..10V, CO2 + Temperatur + relative Feuchte + LCD SCD-220-E00-00 aktiv, 2x 4..20mA, CO2 + Temperatur SCD-221-E00-00...
  • Seite 8 European Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY www.johnsoncontrols.com www.johnsoncontrols.com/locations Metasys® and Johnson Controls® are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. © 2020 Johnson Controls. SCD-xxx-E00-00 Raumklimafühler...