6. SAFETY WARNING
WARNING
FIRE AND EXPLOSION HAZARDS
SPARKS AND OPEN FLAMES ARE STRICTLY PROHIBITED
Paints can be highly flammable and can cause fire.
Do not expose to open flames, electrical goods, cigarettes etc.
SECURELY GROUND SPRAY GUN BY USING A CONDUCTIVE AIR HOSE. ELECTRICAL
RESISTENCE: <1MΩ. - ALWAYS ensure that the spray gun is earthed correctly.
Insufficient grounding can cause fire and explosion due to static electric sparking.
NEVER USE THE FOLLOWING HALOGENATED HYDROCARBON SOLVENTS which can cause
cracks or dissolution on gun body (aluminium) by chemical reaction. UNSUITABLE SOLVENTS:
methyl chloride, dichloromethane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane. BE SURE THAT ALL FLUIDS AND SOLVENTS ARE COMPATIBLE WITH
GUN PARTS.
WARNING
PROTECTION OF HUMAN BODY
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you feel any abnormality
during operation, consult a medical doctor immediately.
ALWAYS WEAR PROTECTIVE GEAR (safety glasses, mask, gloves.)
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
In case of any physical discomfort for skin or eyes, immediately seek a medical advice.
THE USE OF INDIVIDUAL HEARING PROTECTION IS ALWAYS RECOMMENDED, because the
terms of use and the influence of other noises in the job area, could increase the acustic average
value allowed.
Pulling trigger many times during operation, may cause carpal tunnel syndrome.
ALWAYS REST, IN CASE OF TIREDNESS.
WARNING
IMPROPER USE OF THE EQUIPMENT
NEVER EXCEED MAXIMUM OPERATING PRESSURE AND MAXIMUM OPERATING TEMPERATURE.
Use at more than max. operating pressure can cause explosion of Spray Gun resulting in great danger.
ALWAYS RELEASE AIR AND FLUID PRESSURE BEFORE CLEANING, DISASSEMBLING OR
SERVICING. Otherwise, remaining pressure can cause bodily injury due to improper operation or
scattering cleaning liquid.
NEVER POINT SPRAY GUN TOWARDS PEOPLE OR ANIMALS.
TIP OF FLUID NEEDLE SET HAS A SHARP POINT. Do not touch the tip during maintenance to
avoid accidents.
NEVER USE THIS GUN TO SPRAY FOODS or CHEMICALS, otherwise the blend of foreign
substances could cause corrosion of the fluid passages, which could adversely affect health.
NEVER ALTER THIS SPRAY GUN. If done, it can cause insufficient performance and failure or in
extreme cases, explosions.
WARNING
OTHER PRECAUTIONS
IF SOMETHING GOES WRONG, IMMEDIATELY STOP OPERATION AND FIND THE CAUSE
OF FAILURE. Do not use again until you have solved the problem.
DO NOT ENTER WORKING AREAS, WHERE ROBOTS, RECIPROCATORS, ETC. ARE USED,
UNTIL THEY HAVE BEEN TURNED OFF. O t h e r w
ALWAYS USE NEUTRAL CLEANER: pH value shall be 6 to 8, otherwise could cause corrosion.
NEVER USE SPARE PARTS THAT ARE NOT ANEST IWATA ORIGINALS.
WET on WET & FILLER
-
G R A V I T Y S P R A Y G U N S
i s e , t h ey c o u l d
c a u s e i nj u r y .
3