Data sheet
Sheet No.:
A1.102 Rev. B
Date: June 2010
P-series
A
B
A
B
A
B
PD = Double acting
PS = Spring return
E-series
A
B
A
B
ED = Double acting
A
B
11°
Adjustable
range*
-0.5° Closed
91.5°
91.5°
91.5°
91°
Open
A
B
A
B
* only standard on E-Serie actuators
A
B
www.El-O-matic.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.El-O-Matic.com or from your nearest Valve Automation Center USA: +1 813 319 0266 Europe: +31 74 256 10 10 Asia-Pacific: +65 6501 4600
Specification
Pressure range
Torque
Operating media
Temperature
Lubrication
Construction
Finish
Rotation
Double acting
Spring return
Limit stops
ES = Spring return
ACTUATOR TYPE
Bore
Stroke
Weight: Double acting
Spring return
Operating time
Air consumption at
1 atm (cu./in.)
TECHNICAL DETAILS, STANDARD ACTUATOR
: Double acting
20 to 120 psi
: Spring return
80 to 120 psi,, with max. spring set
40 to 120 psi, reduced spring
quantity
: 180° actuators 87 psi maximum
: 1133 to 40,000 in.lb at 80psi supply
See torque datasheets 1.104.01 and 1.104.02
: Air, dry or lubricated and inert gasses
: For sub-zero applications take appropriate measures
: -4° to +176°F
: Factory lubricated for the normal life of the actuator
: Suitable for indoor and outdoor installation
: Polyester non-TGIC based powder coating
(see data sheet A4.204.01)
: 91.5° (-0.5° CW to 91° CCW)
: Standard counter clockwise with port "A" pressurized
(code A, see data sheet A1.503 for other assembly
codes)
: Clockwise fail action
(code A, see data sheet A1.504 for other assembly
codes)
: Standard on E-series. Adjustable range 91°/80°
: Optional on P-series. See datasheet A1.501.01
: For double stroke adjustment. See datasheet
A1.501.05
E12
E25
E40
inch
1.8
2.2
2.8
inch
0.5
0.6
0.7
lb.
1.3
2.9
4.0
lb.
1.5
3.7
5.3
sec.
0.4
0.5
0.7
port A stroke
3.1
6.1
9.8
port B stroke
3.7
6.7
13
European Directives
PED
ATEX
Russian Approvals
El-O-Matic E and P series pneumatic actuators are
available with the GOST-R and Rostechnadzor (RTN)
approvals.
Note
1. Operating time is average with actuator under load
and solenoid valve fitted.
2. Air consumption is the actual free air volume at 1 atm.
3. Pressure is in barg.
E65
E100
E150
E200
E350
3.1
3.6
4.1
4.3
5.7
0.9
1.0
1.2
1.5
1.5
5.3
6.8
10.5
12.8
23
7.9
10.1
15.2
20.1
37
1.1
1.2
1.8
2.3
3.6
20
21
45
49
110
22
30
40
61
116
E/P
: All actuators are suiteable for use
with Group 2 gasses according to
Pressure Equippement Directive
97/23/EC
: Optional : actuators suiteable for
use with Group 1 gasses
: All basic actuators are suiteable
for use in hazardous area's
classified II 2 GD, zones 1 or 2
(Gasses) and 21 or 22 (Dust)
E600
E950
E1600 P2500 P4000
6.9
7.9
9.1
11.8
12.8
1.7
2.0
2.5
2.2
3.2
43
58
94
125
191
61
85
145
194
291
4.5
5.4
6.9
7
12
177
287
445
488
824
189
299
488
568
1,068