Wiring diagram
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
DIMMER
LED
LOAD
(Switching
wire, often
black)
Multiway switching
with multiple retractive switches
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
DIMMER
P
Specifications
Connection voltage:
220-240 VAC 50Hz
Frequency:
2,4 GHz, 868 / 915 MHz
Dimming technology:
Trailing edge and leading edge (R,L,C)
Dimmable LED lamps:
0-250W Trailing (R,C)
0-150W Leading (R,L)
Lamps with electronic transformers:
10-300W
Halogen and incandescent lamps:
10-300W
•
Suitable for both retrofit lamp bulbs and new installations.
•
Two-wire connection - no neutral wire required.
•
Soft start system for longer LED lamp life.
•
Built-in protection for temperature protection and overload.
Setting min. light level
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible to the
left (minimum light output). Do the lights blink? Then use a screwdriver to slowly turn the MIN
potentiometer to the right for stable light. Is the light already stable? Then slowly turn the MIN to the
left for even better dimmability, to just before the point where the lamps start blinking. This is the best
dimmability of the LED lamps.
Setting starting level
Press the dimmer axis 4 times and hold it the fifth time, the connecting lights lamps twice to indicate
that the dimmer is entering the setting mode. Set the desired start level and press and hold the button
to save the setting. The lamps flashes once to indicate that the setting has been saved.
Remark:
1. The time-out for setting is 1 min.
2. Factory setting of the start level:Press the button 5 times and hold it the sixth time, the charge flashes once to return to
the factory setting.
P
Loop-through possible to
adjacent socket/switch.
(Switching wire, often
black)
EN
-or-
ECO-DIM.07 Matter
Universal Matter Led dimmer (R,L,C)
LED
LOAD
Note:
•
This is a two-wire dimmer and it should be connected as shown under the
heading 'Wiring diagram' .
•
Installation of the dimmer on a 230V mains should be carried out by a
qualified professional, taking into account national regulations. Ensure that the
electricity is switched off during all work.
•
You cannot connect more than one dimmer in parallel. To then control the
same load from two points.
•
Dimmer is not suitable for wound/magnetic or core transformers.
This wireless receiver, compatible with various Open Thread border routers (excluding Google Thread
Router Border), utilizes the Matter protocol. It seamlessly connects with any Matter controller featuring
a built-in Open Thread border router. Ensure your Matter controller (e.g., Apple HomePod, Google
Nest Hub, Amazon device) has a Thread border router built-in to easily integrate this device. Thread,
alongside Wi-Fi, is a primary wireless protocol for Matter.
MANUAL