12.5.1. WEEKLY PROGRAM SETTINGS
Press
for two seconds to access the Clock settings. Press
MENU
on the screen. This function allows to set a maximum of three ignitions and three shutdowns per day for each day of the week. When
PROGRAMS ON/OFF
is displayed, press
NO PROGRAMS
(no programs set)
(single program for all days)
DAILY PROGRAM
(program for each single day)
WEEKLY PROGRAM
-
+
Use
to scroll the programs.
Press
MENU
to confirm
DAILY PROGRAM
SELECT PROGRAM NO.
Caption on the
screen
Daily program
DAILY PROGRAM
allows to set the same program for all the days of the week. Press
-
(one ignition and one shutdown per day),
PROGRAM 1
and 3 shutdowns per day)
Select
to display the ignition time.
PROGRAM 1
The screen will display: All 1 ON, time 10:30 with the flashing hour. Press
The screen will display: All 1 ON, time 10:30 with the flashing minutes. Press
The screen will display: All 1 OFF, time 12:30 with the flashing hour. Press
The screen will display: All 1 OFF, time 12:30 with the flashing minutes. Press
Press Menu when
SAVE??
Select
WEEKLY PROGRAM
Caption on the
screen
1 MO
2 TU
3 WE
4 TH
5 FR
6 SA
7 SU
-
+
Press
to scroll and select the day and then
, making sure to include in the program the number and the time of the interventions for each single day of the week. In
DAILY PROGRAM
case of mistakes during the programming operation, press
12.6. REMOTE STARTING FUNCTION (AUX PORT)
Through a specific cable it is possible to switch on/off the stove by using remote device, such as a GSM phone, room thermostat, home au-
tomation system To activate this option ask the installer or a qualified technician, who should use a volt free contact device following this logic:
Open contact = stove is off
Closed contact = stove is on
The activation and the deactivation occurs with a 10 minutes delay from the transfer of the last command. When the remote starting option is
on, it will still be possible to switch on/off the stove from the control unit; the stove will respond by following the last command that has been
received (either start or shut down).
WARNING: the activation of the internal time programmer (see weekly program settings) automatically excludes the remote starting (Aux. port)
to avoid conflicts with the programmed starts.
1 2
MENU
to confirm and select one of the following options:
and access to the number of programs (ignitions/shutdowns) that you can select in one day.
will be displayed on the screen. Press
Corresponding
No program
day of the week
option
Repeated for all
Select Program
the days of the
No. (Select N
week
Program)
is displayed on the screen to set the shutdown time and the following ignitions or shutdowns.
to select the programming day:
Corresponding
No program
day of the week
option
Monday
Tuesday
Press +/- to
Wednesday
select "Prog.
Thursday
No." and Menu
to confirm
Friday
Saturday
Sunday
to access the weekly time settings, displayed as
+
-
+
to set 1, 2 or 3 ignition/shutdown ranges for each day.
One ignition / One shut-
down option
Press +/- to
select "Program
1" and press
Menu to confirm
(2 ignitions and 2 shutdowns per day),
PROGRAM 2
-
+
to change the hour and Menu to confirm.
-
+
to change the hour and Menu to confirm.
-
+
-
+
One ignition / One
shutdown option
Press +/- "Prog.
No. 1" and then
Menu to confirm
MENU
to confirm. Program the days following the same method used for
to exit the program without saving.
0/1
Two ignitions and two
Three ignitions and three
shutdowns option
Press +/- to
select "Program
2" and press
Menu to confirm
+
to display:
PROGRAM 3
to change the minutes and Menu to confirm.
to change the minutes and Menu to confirm.
Two ignitions and two
Three ignitions and three
shutdowns option
Press +/- "Prog.
No. 2" and then
Menu to confirm
PROGRAMS ON/OFF
shutdowns option
Press +/- to
select "Program
3" and press
Menu to confirm
(3 ignitions
shutdowns option
Press +/- "Prog.
No. 3" and then
Menu to confirm

Werbung