12.4. LIST OF ALARMS

The stove control system is equipped with various safety devices to ensure correct operation the following alarms may appear on the
screen:
Description
on the
Alarm meaning
screen
Not under
No air in the
pressure
combustion chamber.
The combustion blower fan
No ejection
is not running.
No electric power
No electricity
during operation.
High smoke
Smoke discharge
temperature
temperature is too high .
Flame interrup-
Shutdown due to too low smoke
tion
temperature.
Thermocouple
Smoke exhaust temperature
(TC) is broken
sensor is broken.
The stove did not start
Start failed
automatically.
Sensor alarm
Stop operation.
The stove has reached the
Service
programmed operating hours.

12.4.1. RESET BUTTON

In case of overheating of the stove due to failure or obstruction of the
ventilation system, intervenes a safety thermostat with manual reset
that blocks the supply of pellets.
Before the stove can be switched on manually, turn off the stove
and remove the power plug. Only once the oven has cooled down,
following steps need to be done to bring it back in operational read-
iness.
To reactivate the features of the stove just do the following:
• Unscrew the protective cap;
• Press the red reset button;
• Screw the protective cap;
• Start the stove.
12.5. DATE / TIME / CLOCK SETTINGS
Press
for 2 seconds to access Menu/Clock. This function allows to set time and date. Press
MENU
be displayed one after the other, so that it would possible to set them: day, month, year, hours, minutes, day of the week. When
displayed, press
to make sure the settings are correct before confi rming them (Save OK will appear on the screen).
MENU
Possible cause
Intake/exhaust circuit
blockage or open door.
The combustion blower fan
is broken or stuck.
Electricity black out or the
plug is not connected.
Excessive pellet supply, ventilation is not running,
smoke exchanger needs to be cleaned.
No pellets,
fl ame is too low at idle.
Wear and tear of
the component.
Start with empty auger or
with dirty combustion pot.
Sensor fault.
The stove has reached the
programmed operating hours.
U N I C AT E R M
Operation to do
Check that there are no obstructions on the intake pipe
Make sure the door is well closed.
Contact your local
customer service center.
Check that the power plug is well plugged in and the power
switch is in the ON position.
Contact your local customer service center for a
general cleaning of the stove.
Check whether storage container (pellet tank) is not empty,
otherwhise contact your local customer service.
Contact your local
customer service.
Manual auger loading (see section 12.2).
Clean the combustion pot.
Contact your local
customer service.
Contact your local customer service for a general cleaning of
the stove and zero setting of the operating hours.