5.2.3 Button and Function Instruction
Schematic Diagram
IPC-3
No. Name or Function
Start or stop
Start auxiliary pump manually, press it, the
1
button of auxiliary
pump runs
pump
Press the button one time can reduce 0.1bar,
2
Reduce button
long time press can reduced rapidly
Press the button one time can increase 0.1bar,
3
Increase button
long time press can increase rapidly
It can start the pump manually, press this button
4
RUN/STOP button
to exit the water shortage state
The indicator flash , it means the pipe is wa-
Water shortage
tershort. It will restart in setting time and the
5
indicator
interval time for restart is 8S, 1min , 10min ,
30min , 1h , 2h ....restart
The light is flashing when working in the setting
Pressure setting
6
indicator
pressure value
auxiliary pump
When the pump stop automatically,the indicator
7
indicator
lights,when stop pump manually,the indicator is off
When the main pump speed operating state or
standby state,the indicator flash quickly.when
8
Pump indicator
the main pump at the constant speed (constant
pressure) work state, the indicator flash slowly.
when the indicator is off,the main pump stop
9
Power indicator
Indicator lights up when power is connected.
10 Current pressure
Display value indicates the current pipe network
display
pressure value,unit:bar
Display value indicates the current setting
11 Set pressure
pressure value,unit:bar. Factory default Settings
display area
is 3bar
English 7