9. RECOGNISING AND REPAIRING OF MISTAKES
Problem
The pump permanent-
ly switches on and off
(Pump clocked)
The pump will not start
The pump will not stop
10. NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are
caused by our units if no changes were made to the equipment. If repairs are carried out by our
authorized service, we are only liable if original spare parts and accessories were used.
11. NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash bin, are
not permitted to be disposed in your household garbage. We are registered at the
German registration department EAR under the WEEE-No. DE79535656.
This symbol means, that you're not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point of
electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
Mögliche Ursache
The system has leaks. Internal
check valve may leak
1. No mains voltage present
2. Too much difference in height
between the device and a
customer (taps)
3. The pump is defective
4. Malfunction of the device
1. The system has greater lea-
kages
2. Malfunction of the device
3. Internal check valve is dirty
Lösung
Vent system
Check system to dripping pipes /
faucets / valves.
Check non-return valve in the unit
for leaks
1. Check the electrical connections
2. Reduce height difference
3. Contact a qualified technician
4. Montact the merchant
1. Check the system
2. contact the dealer
3. Pump + Rinse machine (see 6)