Hose drainage
The Comedes Demecto 12 can also be operated using a drainage hose (Ø9.0mm). To do this,
remove the water tank and attach a drainage hose.
To do this, proceed as follows:
1.Remove the water tank
3. Put the water tank back in place.
and guide the hose through it
the recess of the drainage outlet.
Attention:
Make sure that the hose does not run higher than the hose connection on the appliance
at any point so that the water can drain off undisturbed.
Make sure that the drainage hose is not kinked or blocked. Check this regularly.
Make sure that the end of the hose is not below the water surface of the drain or
similar.
The appliance must be switched off and disconnected from the mains after each use and
before attaching or removing accessories by pulling the mains plug out of the protective
contact socket after switching off. Let the appliance cool down to room temperature before
cleaning and/or storing it.
Automatic defrost
The dehumidifier is equipped with a temperature-dependent defrost function.
At a room temperature between 5°C and 16°C, the unit starts defrosting every 45 minutes.
During the defrosting process, the power LED flashes.
EN-13
2. Attach the drainage hose to the drain of
the drip tray.
www.comedes.com