TROUBLESHOOTING
PROBLEM
Compressor will not
run
Motor hums but cannot
run or runs slowly
Current limiting
protector
Protector cuts out
repeatedly
Air tank pressure drops
when compressor
shuts off
CAUSE
Loss of power or
overheating
NO electrical power
Blown shop/house fuse Check fuse/ breaker
Shop/house breaker
open
Current limiting
protector open
Pressure switch bad
Tank is full of air
Low voltage
Wrong gauge wire or
length of extension
cord
Shorted or open motor
winding
Defective check valve
or unloader
LOW voltage
Lack of proper
ventilation/room
temperature too high
Wrong gauge wire or
length of extension
cord
Loose connections
(fitting , tubing, etc.)
Loose drain valve
Check valve leaking
POSSIBLE SOLUTION
Check for proper use of
extension cord
Check to be sure unit is plugged
in
Replace shop/house blow fuse
Reset shop/house break-
er, determine why problem
happened
Motor will restart when cool
Compressor will tum on when
tank
Pressure drops to cut- in
pressure
Check with voltmeter
Check for proper gauge wire and
cord length
Take compressor to service
center
Take compressor to service
center
Check with voltmeter
Move compressor to wel
ventilated area
Check for proper gauge wire and
cord length
Check all connection with soap
and water solution and tighten
Tighten drain valve
Take compressor to service
center
DANGER
Do not disassemble check valve,
tank drain valves or safety relief
valve with air in tank- bleed
tanks.
31