Commissioning/start-up
NOTE
The unit may be damaged, if the water flow is suddenly interrupted downstream of the outlet
(e.g. by a slide valve). The sudden interruption can cause a temporary pressure increase of over
1 bar (hydraulic shock).
Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a
filter system, first take the filter system out of operation.
Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a
filter system, start up the filter system last.
As an alternative, install the slide valve upstream of the inlet.
NOTE
Ensure that the filter will not overflow. Danger of emptying the pond.
It takes approx. 1 to 2 months before the micro-organisms in new filters are fully estab-
lished. During this time – or at a water temperature of <10 °C – biological cleaning may be
limited.
− When using filter starter, medicines or pond water treatments, leave the UVC clarifier
switched off for at least 36 hours so as not to impair their efficacy.
Prerequisite
• First switch on the pump, then the UVC clarifier.
• Check all connections for leaks.
Switching ON/switching OFF
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.