Floor in front of and under the fireplace
Floors made from combustible materials, such as carpets, parquet floors or cork is
to be protected by a shield of non-combustible material – for example ceramics,
stone, glass or steel – placed under the fireplace so that it should reach out to
50 cm in front and 30 cm besides.

2.4 Connection of the fireplace

The connection for attaching to the chimney must be able to withstand at least
400°C.
Before connecting the stove the local authority responsible for approving
Connection pieces must be firmly connected to the stove and to each other and
must not leak. They must not project into the open diameter of the chimney. The
connection piece between the stove and the chimney must have the same diameter
as the pipe socket on the stove. Horizontal connection pieces of over 0.5 m must
rise towards the chimney at an angle of 10 degrees. Any pipes which are not heat
insulated or vertical must not be longer than 1 metre.
The requirements of the Fire Regulations (FeuVO) apply, as well
as local building regulations such as for the chimney standards
DIN 4705, DIN EN 13384, DIN 18160 and DIN EN 15287.
Connection pieces must be tested to DIN EN 1856-2. Measure-
ment X (distance from flammable construction and other materi-
als) must be as defined by the manufacturer of the connection
piece.
Fitting to a chimney with a functional height of less than
4 m, or if several toves are being fitted, less than 5 m, is not
permitted. (See: Data for chimney calculations / Chapter 3.)
A maximum of two other fires can be connected to the chimney to be
conected to the stove (Germany).
For safety reasons it is not permitted to use a steam extractor hood to re-
move air when the stove is producing heat.
PLEASE NOTE:
heating systems must be consulted!
PLEASE NOTE:
The fire-place can usually be joint-
ed to the chimney with an arch.
With weak chimney draught, the
fireplace is to be connected to the
chimney through a vertical flue gas
pipe facilitating discharge.