installation, apply a standard double pole switch that ensures complete disconnection from the mains in category III
overvoltage conditions, in accordance with the installation rules. • Warning! The power cable must be replaced by the
authorised technical support service or by a person with similar qualifications.
LED temperature adjustment
Once the product has been installed, before refitting the grease filter and the perimeter suction panel, it is possible to
adjust the temperature of the LED, from warm light to cool light, in order to match it with the light in your room.
The available temperatures are:
W = 3000K warm
N = 3500K medium warm
C = 4000K cool.
OPERATION
Please note! This hood features an automatic operation system (see the paragraph "VOC sensor calibration").
Calibration occurs automatically each time the hood is reconnected to the electrical network (e.g.: the first time it is
installed after a blackout). It can also be performed manually (see the paragraph "VOC sensor calibration - manual").
During calibration, which lasts 5 minutes, the controls will flash and only the light button can be used.
L5
L1
L3
L2
L4
T1
T2
T3
T4
T5
T1= LIGHTS ON/OFF.
T2= Motor OFF or Reduce speed (e.g.: from 4 to 1).
From whichever position the hood is in, pressing the key for 3" switches off the motor.
T3= Increase suction speed.
Press T3 to switch the hood on at speed 1, keep pressing the key to increase the motor speed from speed 2 to intensive.
Press and hold the key for 3" to automatically activate INTENSIVE speed.
With each speed, the respective LED lights up.
Speed 1 LED L1
Speed 2 LED L2
Speed 3 LED L3
Intensive speed LED L4 (flashing).
Intensive speed is timed. Standard timing is 5', after which the hood switches to speed 3.
To deactivate the function before the time expires, briefly press T2; the hood will switch to speed 3.
To switch off the motor, press and hold key T2 for 3".
T4= Sensor ON/OFF. Activates or deactivates the VOC sensor function.
By pressing the key, the VOC function is activated and LED L5 becomes blue. When the VOC sensor function is enabled,
the motor must be switched off (if it was previously ON). The hood will switch on at the most suitable speed based on the
fumes detected by the sensor the hood is equipped with.
T5= Operating status indicator
VOC sensor calibration
The calibration of the sensor lasts about 5 minutes; press T4 to switch on the hood at speed 1 (LED L5 on steady), while
LEDs L1, L2, L3 and L4 start flashing cyclically.
Calibration is complete when LEDs L1, L2, L3 and L4 go out, followed by an acoustic signal (beep).
During calibration, it is only possible to switch the lights on and off.
Calibration is necessary to allow the sensor with which the hood is equipped to work correctly and can be:
automatic: each time the hood is reconnected to the mains (e.g. the first time it is installed or after a power failure).
manual: to be performed when automatic operation is unsatisfactory and when normal environmental conditions persist in
the kitchen.
Manual calibration is activated by pressing and holding key T4 for 6".
Hob selection
To use the VOC function in the best way possible, it is necessary to select the correct type of hob (gas - induction or
electric).
With the hood and the VOC sensor off, simultaneously press T1 and T4 until an acoustic signal (beep) is emitted, release
the keys and when either T2 or T3 is pressed again, the desired hob can be selected according to the following diagram:
LED 1: gas hob
7