Preparing for first use
Press the OK key
y
to confirm.
Wait 10 seconds until the device automatically quits
the settings mode.
Switching automatic dialling on / off:
You can switch off the automatic dialling function.
The device calls all the stored telephone numbers if the
automatic dialling function is switched on when an
alarm is triggered.
The LC display shows
if the automatic dialling func-
tion is not switched on. Factory setting: "CALL ON" (dial-
ling function switched on)
Enter the current password.
r
Press the PROG key
a sufficient number of times
until the
symbol flashes at the top of the LC dis-
w
play
.
y
Press the OK key
to confirm.
o
i
Use the
key
and
key
ON" (dialling function switched on) or "CALL OFF"
(dialling function switched off).
y
Press the OK key
to confirm.
Wait 10 seconds until the device automatically quits
the settings mode.
Selecting the number of dialling processes:
You can select the number of times the automatic dial-
ling function dials the numbers as between once and 5
times. Every stored telephone number will be called this
number of times, whether or not the call is answered.
Factory setting: 3 times
Enter the current password.
r
Press the PROG key
a sufficient number of times
until the word "CYCLE" flashes at the top of the LC
w
display
.
y
Press the OK key
to confirm.
Using the
key
o
and the
number of automatic dialling processes (1/2/3/4/5).
y
Press the OK key
to confirm.
32
GB/MT
Wait 10 seconds until the device automatically quits
the settings mode.
Setting the entry delay:
Here you can set the time you have, from the time any
motion is detected by the device in the armed state, to
cancel the alarm before the siren starts or the telephone
numbers are automatically dialled.
Factory setting: 20 seconds.
Enter the current password.
Press the PROG key
until the word "ENTRY" flashes at the top of the LC
w
display
Press the OK key
Using the
length of the entry delay (0 / 5 / 10 / 15 / 20 seconds).
Press the OK key
to select "CALL
Wait 10 seconds until the device automatically quits
the settings mode.
Setting the date / time display:
1.
Enter the current password.
2.
Press the PROG key
until the word "TIME" flashes at the top of the LC
w
display
3.
Press the OK key
4.
The LCD display now shows:
05 – 01 – 01
= Year – Month – Day Hours - Minutes
5.
Select the appropriate field by pressing the OK key
the required number of times.
The selected field flashes.
6.
Using the
desired setting.
7.
Press the OK key
key
i
select the
8.
Repeat items 6 and 7 until all the values have been
entered.
r
a sufficient number of times
.
y
to confirm.
key
o
and the
key
i
select the
y
to confirm.
r
a sufficient number of times
.
y
to confirm.
12 - 00
o
i
key
and the
key
select the
y
to confirm.
9.
Wait 10 seconds until the device automatically the
settings mode.
Reset:
If you wish to delete all the settings or you have forgotten
your password, you can initiate a reset as follows:
r
Keep the PROG key
pressed until you hear a pip
sound.
Now immediately press the Pause key
hear a pip sound.
Now remove the battery and disconnect the mains
adapter. After 2 minutes insert the battery again
and/or reconnect the mains adapter.
Now all the factory settings and the factory-installed
password ("000") are restored.

Positioning the alarm unit

1.
Limiting the detection range/angle:
In the as-supplied condition the motion detector has a
detection angle of approx. 100 ° and detection range of
approx. 6 m (at a mounting height of 0.5 - 2m) (see Fig. G).
You can modify the detection range and angle by adjusting
the motion detector.
To limit the detection angle use one of the two supplied
W
masking stickers
(complete or cut to size).
See Fig. H
Limited horizontal detection angle (approx. 40 °) e.g.
as a crossing detector.
y
See Fig. I
You can disable the motion detector by applying the
whole masking sticker, e.g. if detection is to be per-
formed by an externally connected detector (see the
section on "Optional connections").
t
until you