open hole in corner angle (2215 / 2216) (4.7).
Note: Position (2240) and (2241) using the
locating edge on (2215 / 2216).
Place pane D into the guide in horizontal bar
(2237) and assemble onto (2240) and (2241)
(4.8) ensuring correct fi tting into (2248) and
(2249)
.
Connect door guide bar (2251) to horizontal
bar (2237) loosely from the outside with two
nuts and bolts
.
Depending on which direction the door should
open, align the door guide bar (2251) to the
left or to the right.
5. ROOF ASSEMBLY
For Triton 5000, 6200 & 7500:
Assemble parts (2220) / (2221)
, or (2225)
, together using
/ 7500)
(Triton 5000)
connecter (2229) and 8 nuts and bolts (5.1).
Note: The 4 inside nuts and bolts should only
be connected loosely.
Slide parts (2227)
(5.2) or (2228)
(Triton 5000)
(5.3) over the join between
(Triton 6200 / 7500)
the ridge bars.
Connect the assembled ridge bar (2220 -
2226) onto roof corner bars (2240) and (2241)
by sliding the prepared extra bolts into the
open hole in the ridge bar (5.4).
Insert 1 extra bolt to connect roof brace (1056)
into each roof middle bar (2242) (5.8) and
(2243) (5.9).
On two adjacent roof bars insert 1 extra bolt to
connect roof vent sill bar (2260) in step 6.
Please repeat this at a
Triton 6200 & 7500:
second location.
Include 1 extra bolt adjacent to
Triton 2500:
that included in (2240) / (2241) in step 3.
Connect roof middle bars (2242) and (2243)
between the eave angle bars, noting the
locating edge (5.5) (5.6) (5.7) and the ridge
bar (5.8) (5.9).
Now position your frame on the prepared
base/foundation and connect loosely. (Please
only tighten these bolts after the house is fully
glazed.) Adjust the frame until it is completely
square and tighten all bolts.
Please do not over tighten.
6. SIDE / ROOF GLAZING
Slide eave connecter
Triton 5000, 6200 & 7500:
(2219) into the joining ends of eave bars
(2210) or (2211) (6.2). On both sides of (2219)
connect screw (1006) in the prepared holes
(6.2).
Slide panes E into the appropriate guides in
020.01.1001
the vertical bars (6.4).
Slide panes F and G into the appropriate
guides in the roof bars (6.5).
Prepare 4 bolts in each eave bar and connect
to eave angles (2215) or (2216) (6.6) (6.7).
Connect roof vent fi xers (6056) to sill bar
(2260) using screws (1006) (6.8). Connect
(2260) in the desired opening for the roof vent
fi tting it over the top edge of the assembled
pane G (6.9).
7. DOOR
Attention: Do not stand the assembled door
(Triton 6200
on door gliders (2214) to avoid damaging
them.
Screw (1006) into both sides of door bottom
bar (2255) and then push door gliders (2214)
into both ends (7.2).
Assemble (2252), (2253), (2254) and (2255)
as shown (7.3) (7.4) (7.5).
Slide the panes H into the appropriate guides
in the middle bars and connect door side bar
(2258) (7.6).
Insert door guides (2271) into the top end of
door side bars (2252) and (2258) (7.5).
Slide brush seal (2270) into both side bars
(2252) and (2258) (7.7).
Slide (2214) onto sill bar (2209) and (2271)
into door guide bar (2251) as shown.
Cutting brush seal (2270) on the desired side,
use screw (2289) to connect door knob (2285)
as shown.
Connect (2257) to door support bar (2250)
using bolt (2001). Connect (2257) to the end
of (2251) by inserting bolt (1001) in the bolt
channel in (2251) (7.8).
Connect the bottom end of (2250) to corner
bar (2230) by inserting bolt (2001) into the bolt
channel in (2230) (7.9).
Once the door is in place connect nut (1002)
and bolt (2001) into the open end of (2251) as
door stopper.
8. ROOF VENT
Connect roof vent bars (2261), (2262) and
(2263) (8.2) (8.3).
Slide pane J into the apropriate guides and
connect side bar (2262) (8.4).
Attach roof vent opener (1067) using screws
(1006) and place plastic cap (1019) over the
end (8.5).
Position the roof vent in the ridge bar from one
end (8.6) (8.7) (8.8) and slide it to the prepa-
red opening (8.9).
FINISHING
If desired, it is possible to seal the greenhouse
at the edges using neutral silicone. Silicone is
not in cluded.
Place the warning label inside the house.
A full range of greenhouse accessories, to
help you make the most of this product, is
available from your stockist. Please inform
yourself as to the possibilities.

SAFETY NOTICE

In the event of high wind conditions, close the
doors and all vents.
In the event of heavy snowfall, clear the roof
of the building or take suitable measures to
support the roof. Heat the building in winter.
COMMENTS
For the complete protection of your new
green house, we advise you to include it in
your house insurance. Please take note
of possible building rules relating to the
positioning of greenhouses.
Please stick the included greenhouse model
label onto door bar (2253) after success fully
assembling this product. This information is
important in the event that replacement parts
are later required.
Please keep these assembly instructions in a
safe place, for future reference!