Modbus - Register (Firmware-Vers.:1.20; Matrix: 127; 2023-10-23)
Schutz:
A – Anzeigewert (Read-Only)
C – Unter dem Codewort-Schutz (Write)
E – Unter dem Metrologischen Eichtaster (Write)
N – Ohne Einschränkung (Write)
Volumen / Zählwerke
Koor-
Name
dinate
A01
VolumeBase
A02
VolumeMeasure-
ment
A03
VolumeBaseEr-
ror
A04
VolumeMeasure-
mentError
A05
VolumeMeasure-
mentTotal
A20
Counter-
ResolutionExp
A21
CounterDigits
Durchfluss
Koor-
Name
dinate
B01
Qb
B02
Qm
B05
QmMin
B06
QmMax
B08
QmUg
B09
QmMinTime
B10
KKAm2
B11
KKAm1
B12
KKA0
B13
KKA1
B14
KKA2
B16
SystemStatus
Modbus-
Schutz Datentyp
Register
300
A
IS_ICOUN-
TER32
302
A
IS_ICOUN-
TER32
304
A
IS_ICOUN-
TER32
306
A
IS_ICOUN-
TER32
308
A
IS_ICOUN-
TER32
313
E
IS_INT16
314
E
IS_UINT16
Modbus-
Schutz Datentyp
Register
318
A
IS_FLOAT
320
A
IS_FLOAT
521
E
IS_FLOAT
523
E
IS_FLOAT
527
E
IS_FLOAT
529
E
IS_UINT16
530
E
IS_FLOAT
532
E
IS_FLOAT
534
E
IS_FLOAT
536
E
IS_FLOAT
538
E
IS_FLOAT
341
A
IS_MENU
Min. Max.
De-
fault
0.0
9999999.99 0.0
0.0
9999999.99 0.0
0.0
9999999.99 0.0
0.0
9999999.99 0.0
0.0
9999999.99 0.0
-3
3
0
9
9
9
Min.
Max.
Default
0.0
250.0
4.0
16.0
2500.0
400.0
0.0
250.0
1.0
0
10000
10
-100.0
100.0
0.0
-100.0
100.0
0.0
-100.0
100.0
0.0
-100.0
100.0
0.0
-100.0
100.0
0.0
Handbuch RSM 200 · DE02 · 16. Februar 2024
APPENDIX
139
Einheit
&VolumeUnit
&VolumeUnit
&VolumeUnit
&VolumeUnit
&VolumeUnit
Einheit
&FlowUnit
&FlowUnit
&FlowUnit
&FlowUnit
&FlowUnit
s