WIRING DIAGRAM
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
L
L
Loop-through possible to adjacent
socket/switch.
-or-
SINGLE-POLE SWITCHING
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
LED
LOAD
L
L
SETTING LEADING OR TRAILING EDGE
The dimmer features two dimming techniques: Leading edge (RL) and Trailing edge
(RC). By means of the slide switch on the dimmer, the desired technique can be
selected. Most dimmable LED lamps work best with the Trailing edge (RC) dimming
technique. If the packaging of the lamps does not indicate which technique is used
to dim the lamps, you can try both techniques to choose which one works best.
SETTING MIN. LIGHT LEVEL
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible to the left (mini-
mum light output). Do the lights blink? Then use a screwdriver to slowly turn the MIN potentiometer to
the right for stable light. Is the light already stable? Then slowly turn the MIN to the left for even better
dimmability, until just before the point the lamps start blinking. That is the best dimmability of these LED
lamps.
SETTING MAX. LIGHT LEVEL
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible to the right
(maximum light output). Do the lights blink? Then turn the MAX potentiometer slowly to the left for
stable light. Is the light already stable? Then slowly turn the MAX to the right for even better dimmability,
to just before the point when the lamps start flashing. This is the best dimmability of the LED lamps.
LED
LOAD
Switching wire (Often black)
MULTIWAY SWITCHING
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
LED
LOAD
L
L
R,L = Leading edge
R,C = Trailing edge
EcoDim B.V.
Dr. Huber Noodtstraat 89
7001 DV, Doetinchem, Netherlands
EN
(Imported by NJ Trading B. V .)
Manual
ECODIM.03 PRO
Led dimmer trailing edge
Please note:
This is a two-wire dimmer and it should be connected as shown under the
heading 'Wiring diagram' .
Installation of the dimmer to a 230V mains power supply should be carried
out by a qualified professional, taking into account national regulations.
During all work, make sure that the electricity is switched off.
You cannot connect more than one dimmer in parallel. To then operate the
same load from two points.
Dimmer is not suitable for wound/magnetic or core transformers.
leading edge