Panel Removal
Before releasing the mounting brackets, disconnect the panel from the mains by doublepole switch. Using tools, release
erection bolts and lift the panel vertically upwards to release the brackets from the screws. It is also necessary to disconnect
the power supply cable from the wall junction box.
Technical Data
Dimensions (mm)
TYPE
MR 300
500x500x30
MR 500
700x500x30
MR 800
900x600x30
MR 1000
1100x600x30
MR 1200
1300x600x30
MR 1500
1500x600x30
The panel may be mounted to the grounds of flammability classes C and D.
12
Weight
LxWxD
(kg)
20
28
43
53
62
72
Electric
Output
current
Voltage
(W)
(A)
300
1,30
500
2,17
800
3,48
230 V
1000
4,35
1200
5,20
1500
6,50
Max.
Class
surface
temp.
II
110 °C
AC
Protection
IP 44