Herunterladen Diese Seite drucken

WilTec 50744 Bedienungsanleitung Seite 11

Heizöl- und dieselpumpe
Vorschau ausblenden Andere Handbücher für 50744:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection
Use a suitable power supply. This means a this a 12 V car battery or a 24 V truck battery.
Do NOT install on a 230 V power supply at 50Hz.
The pump is turned on and off by means of a built-in ON-/OFF switch. The indicator lamp inside
the switch lights up if the engine is started.
The engine is protected against overloading or blocking by means of a built-in motor protection. In
case of overheating the pump is turned off automatically due to the overheat protection and after
its cooling, the pump is automatically started.
Suction pipeline
Connect a suction hose (plastic hose minimum 3/4"with spiral reinforcement) directly or with a
threaded fitting to the suction connection (intake connection) of the pump (1" Inside thread) of the
pump.
The suction hose that is used should have a suction valve. In case the suction valve cannot be
used, a check valve should be installed in the suction line.
Position the suction line on a rising gradient from the removal point towards the pump. Avoid lay-
ing the suction line over the pump height, air bubbles in the suction line delay and prevent the
suction process.
Suction and pressure line must be placed in such a way so that they exert no mechanical pres-
sure on the pump.
The suction valve should lie deeply enough in the medium to be pumped. This way the drop in
the fluid level prevents the pump from dry running.
A leaking suction line prevents the suction of the pumped medium by sucking in air.
Avoid sucking foreign particles (sand etc.).
Commissioning
Set up the pump on a fixed, flat place, where the temperature does not exceed 40°C. The pump
has to be placed in a horizontal position, so that the bearings can function properly, screw the
pump tight to its bottom part.
Bring the suction line ready for operation. The suction hose should not be narrower than the suc-
tion connection. If the suction lift exceeds 4 m, use a suction line with a larger diameter.
Proceed with the electrical connection.
Cleaning
The heating oil pump must be cleaned only by using mild cleaning agents as well as a damp cloth and
soapy water. Damage caused by inappropriate cleaning agents is not covered by warranty.
© by WilTec Wildanger Technik GmbH
http://www.wiltec.info
Seite 11