Herunterladen Inhalt Inhalt Diese Seite drucken

Fischer Panda Panda 12000x PVMV-N Handbuch Seite 163

Fahrzeug generator
Inhaltsverzeichnis

Werbung

Panda xControl
No..
Description
25
Battery voltage
26
RPM failure
29
Power out relay
65
AC-Voltage
66
AC-Frequency
67
AC-Current
68
AC-Power
70
Servo power
72
Temperature Cylinder
head
73
Temperature winding
74
Temperature Exhaust
75
Temperature Electronic
77
Starter power
78
Glow circuit
80
Fuel supply
81
Stop solenoid - Hold
82
Stop solenoid - Pull
83
Optional DC out
89
Battery voltage
93
Power out relay
130
No Panel found
131
Communication FP BUS
132
Service interval
133
BUS Module lost (3ph-
measurement)
134
BUS Module lost (DC-
measurement)
135
Sync failure
136
Communication
motorcontroller
137
Airfilter
139
Syncmodul
140
loadbancing
141
Configuration syncmodul
246
Service done
251
Admin Param changed
255
Reserved
9.6.16
Cause
battery voltage to low
RPM out of range
Failure power out relay
Voltage to high
Frequency to high
Current to high
Load to high
Power to high
Temp. value to high
Temp. value to high
Temp. value to high
Temp. value to high
Starter failure
Glow circuit failure
Failure fuel supply
Failure stop solenoid hold coil
Failure stop solenoid pull coil
Failure optional DC out
Battery voltage to high
Failure power out relay
Wrong patch cable/wrong contact
Communication failure
Service due
generators cannot be synced
No data from motorcontroller
Error Airfilter
No data from Syncmodul
Generator takes
less of load
Syncmodul available but not
selected
user
user
Explication
Failure fuel supply
Fuel empty
Short circuit
mechanical blocked. Power
consumption to
high, short circuit
short circuit
Starter defect
short circuit
defect
short circuit
defect
short circuit
short circuit
short circuit
Short circuit or defect
check cable/harness
lost communication with Panel
second generator can not be
switched to the running generator
short circuit
defect
Bad airfilter
short circuit
defect
Generator produces not enough
power
Crippled mode only
Service interval reset
Parameter changed in Admin level n.a.
Kapitel/Chapter 2: Panda xControl - Seite/Page 163
Warning
Gen.Stop
yes
yes
n.a.
yes
n.a.
n.a.
yes
yes
yes
yes
yes
n.a.
yes
n.a.
yes
yes
yes
yes
yes
yes
yes
yes
yes
n.a.
yes
n.a.
yes
n.a.
yes
n.a.
yes
n.a.
yes
n.a.
yes
n.a.
yes
yes
yes
Yes
n.a.
yes
n.a.
yes
yes
n.a.
yes
n.a.
n.a.
yes
Yes
Yes
Yes
Yes
Yes
No
n.a.
n.a.
n.a.
n.a.
n.a.
Info
n.a.
yes
yes
yes

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Panda 15000x pvmv-n