KLAMER Luftentfeuchter 12 Bedienungsanleitung Seite 11

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product diagram
2
1
Control panel & display
1
Air outlet
2
Carrying handle
3
Humidity sensor
4
Note
The air exiting the top is significantly drier than the ambient air. To measure the humidity
in the environment, it is recommended to keep 2 meters away from the dehumidifier.
3
4
5
6
Air inlet
5
Water level indicator
6
Water hose opening
7
Water tank
8
19
Installation
For efficient operation of the
dehumidifier, minimum distances
must be observed. These are shown
on the illustration below and are as
follows:
- Distance to the side: At least 30cm
- Distance to the front: At least 20cm
- Distance to the back: At least 20cm
- Distance to the top: At least 30cm
Important notes on refrigerants
Caution: Fire hazard!
This device contains the flammable refrigerant R290. There is a fire hazard if
7
the refrigerant leaks and is exposed to an external ignition source!
8
Technical Data
Maximum refridgerant
charge amount
Minimum rated airflow
Recommended
floor
area for operation or
storage
Minimum floor area for
operation or storage
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater. Do not pierce or burn.
Information on handling refrigerants
Make sure that no components of the refrigerant circuit are damaged.
Escaping refrigerant may not be noticed as it is odorless. Units with flammable
refrigerants may only be installed and used in well-ventilated rooms.
Work on a refrigerant circuit may only be carried out by persons who have a
currently valid certificate from an accredited assessment body to ensure the
safe handling of refrigerants in accordance with an industry-recognized
assessment specification.
WARNING
Value
Always
keep
openings clear of obstruction.
R290/40g
Servicing or repairs of this unit shall
only
be
performed
100m3/h
manufacturer or as recommended
by the manufacturer.
4-30m2
The appliance shall be stored in a
well-ventilated area where the room
size corresponds to the room area as
4m2
specified for operation.
20
> 30cm
the
ventilation
by
the