Herunterladen Inhalt Inhalt Diese Seite drucken

Summer Stop; Connecting A Chimney Or Open Furnace To The Flue - Nordica ANTHEA Anweisungen Für Aufstellung, Gebrauch, Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ANTHEA – VENERE

13. SUMMER STOP

After cleaning the hearth, chimney and hood, totally eliminating the ash and other eventual residues, close all
the doors of
the hearth and the relevant registers and disconnect the appliance from the chimney.
We suggest performing the cleaning operation of the flue at least once per year; verifying in the meantime the
actual status of the rope seals which cannot ensure the good operation of the equipment if they are not in
good condition and are not making a good seal! In this case the seals must be replaced.
In presence of dampness in the room where the stove has been placed, we advise you to put absorbent salts
into the hearth.
If you want to keep for long the aesthetic look of the stove it is important to protect its internal walls in row cast
iron with neutral Vaseline.

14. CONNECTING A CHIMNEY OR OPEN FURNACE TO THE FLUE

The smoke channel is the section of tube that connects the product to the flue, in the connection these simple
but very important principles must be followed:
for no reason must the smoke channel be used with a diameter lower than that of the neck of the outlet
with which the product is fitted;
each metre of horizontal route of the smoke channel causes a small leak of charge which should be
compensated for by raising the flue;
the horizontal section must never be higher than 2 m (UNI 10683-2005);
each bend of the smoke channel considerably reduces the draught of the flue which must be
compensated for by raising it suitably;
the UNI 10683-2005 Regulation –Italy requires that the bends or variations of direction must in no case
be greater than 2 including the emission into the flue.
Wanting to use the flue of a
chimney or open furnace, it
will be necessary to close
the hood hermetically below
the inlet point of the smoke
channel pos. A Picture 10.
If the flue is too large (e.g.
cm 30x40 or 40x50) it is
necessary to duct it with a
stainless steel tube of at
least 200 mm of diameter,
pos. B taking care to close
the space between the tube
itself
and
the
immediately
below
chimney cap pos. C.
For any
further information,
please contact your Dealer!
7194201 Rev.06 – EN
flue
the
Picture 10
C - Plugging
B
A – Hermetic closure
Inspection
hatch
27