4
Adjust the image.
Adjust the image that is taken by the Sensor
to make it easy to measure. Here, the
position is corrected by searching to enable
measurements even if the position of the
measurement object is not consistent.
Press [Image adjustment].
Press an unused number and then
press [Add pos. comp.] on the menu.
Press [Search position comp.].
Press [Teach].
Press [Graphics+Details].
Continuous measurements will be
performed. Input images of some samples
to see if the judgements are correct.
2
If correct judgements are not made,
adjust the judgement parameters.
Press [
].
Press [Adjust judgement].
Press [
].
Press [Auto judgement].
You can use prepared samples to
automatically set the best judgement
parameters.
Input a sample of a good object and press
[OK Teach].
Input a sample of a bad object and press
[NG Teach].
Repeat these steps for at least two
samples each.
Place the object that is to be used as the
measurement reference in front of the camera.
Move the rectangle so that the characteristic
part for position compensation is inside it.
Drag the
rect-
angle to
move it.
Drag a
corner to
size the
rectangle.
Check the area, press the [OK] Button, and
then press the [TEACH] Button. The
characteristic part and reference position for
position compensation will be registered.
Press [OK].
You can add filter items to adjust the image
to make it easier to measure. Refer to the
User's Manual for details.
2-2 Measurement Settings
Select items for the desired measurement and register
an image as the reference for the measurement.
1
Select the inspection items.
Example to Register Search as the Messurement Method
Press [Inspect]. Next, touch [Inspection].
Press an unused inspection item number and
then press [Add item.] on the menu.
Press [Search].
Press [Back].
The best judgement parameters will be set
automatically.
4. Operation
1
Switch to the Run Mode display.
Press [Run].
Then press [Switch to Run mode].
2
Save the settings.
Press [Yes].
3
Execute measurements.
Measurements will be executed according to
the trigger signal input. And the result of
measurement will be output to an external
device.
2
Register the measurement reference.
Press [Teach].
Place the object that is to be used as the
measurement reference in front of the camera.
Move the rectangle so that the mark to be
meaured is inside it.
Check the area, press the [OK] Button, and
then press the [TEACH] Button. Register the
image as the measurement reference.
Press [Back].
3
Adjust the judgement parameters.
Press [Judgement].
Adjust the judgement parameters while inputting
sample images. Press the judgement condition
parameter to adjust and set the upper and lower
limits for an OK judgement.
3
Note
There are six types of displays that can be used, as shown below.
e six typ
Press the
e
B
Button and then press [Select display] to display the
following selections.
selectio
Displaying the Most Recent
Displaying Measurement
Measurement Values
Values Over Time
Histogram
Graphics
Variations in
Measurement Values
Frequency
Graphics + Details
Trend Monitor
Measurement values
All Results/Region
Statistical Data
Measurement values since
power was turned ON
Note
• To return to the Setup Display, press the
e
Button and then press
B
[Sensor settings].
• To switch to another Sensor, press the
e
B
Button and then press
[Switch sensor].
4
Press the parameter to set.
Lower limit
Press [OK].
The calculation settings can be used to perform
calculations using the results of multiple
Drag a corner
inspection items.
to size the
rectangle.
Refer to the User's Manual for details.
Drag the
rectangle to
2-3 I/O Settings
move it.
The data that is output to external devices and
the input signal assignments can be changed.
(Changes are not normally required.) For
example, the following can be input or output.
• Judgements for individual inspection items
can be output.
• Commands to register models can be input
from an external device.
• If you want to output data externally
Refer to the User's Manual for details.
3. Testing
Tests are made with some samples to see if
correct measurements are possible.
When Test Mode is entered, images are
measured continuously. A trigger input is not
required. Measurement results are only displayed.
They are not output to an external device.
1
Perform tests.
Press [Test].
Then press [Continous test].
Menu Structure
Power ON
Initial startup
Setup Mode
Inspection items are set and adjusted.
[Image] Tab Page
Adjust images to the best input status.
Camera setup
Trigger setup
Image adjustment
[Inspect] Tab Page
Select the inspection items and register
the reference image and standard
values.
Inspection Items
Search
Shape Search II
Sensitive Search
Edge Position
Edge Width
Edge Pitch
Area
Teach
FQ2-S4-
[In/Out] Tab Page
Make settings to output measurement results.
Log setting
I/O setting
I/O monitor
[Test] Tab Page
Test and adjust the set inspections.
Continuous test
Save data
When a Sensor that is already set up is connected
Run Mode
The inspections that were set on the Setup
Mode are used to perform measurements.
Upper limit
Color Data
Labeling
OCR
Bar code
2D-Code
2D-Code (DPM)
Judgement