Herunterladen Diese Seite drucken

Velleman DVM030 Bedienungsanleitung Seite 16

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 74
1.
The detection result is for reference, do not determine the voltage by
NCV detection ONLY.
2.
Detection may interfere by socket design, insulation thickness and
other variable conditions.
3.
The external interference sources, such as flashlight, motor, etc, may
cause the wrong detection.
10.9 LINE (LIVE WIRE RECOGNITION) TEST
1.
Set the rotary switch to LINE position, connect the black test lead to
COM jack and red test lead to VΩ jack, hold the insulation part of black
test lead and not put into circuit under measurement; contact the red
test lead to live wire, the buzzer of meter will be activated and red LED
will be flickered, when the red test lead connect the earth line, the
buzzer does not sound and LED will not flicker.
Notes
1.
When the circuit is in serious leakage (approx. over 15V), the red test
lead even contact earth line, the buzzer of meter will be sounded and
LED will be flickered.
10.10
MAX/MIN
1.
Press the MAX/MIN button to activate the MAX/MIN recording mode,
the display icon "MAX" will appear, the meter will display and hold the
maximum reading and will update only when a new "max" occurs. This
display icon "MIN" will appear, the meter will display and hold the
minimum reading and will update only when a new "min" occurs.
2.
To exit MAX/MIN mode press and hold MAX/MIN button for 2 seconds.
10.11
RELATIVE MODE
The relative measurement feature allows you to make measurements
relative to a stored reference value. A reference voltage, current, etc. can
be stored and measurements made in comparison to that value. The
displayed value is the difference between the reference value and the
measured value.
1.
Press REL button to store the reading in the LCD display and the REL
indicator will appear on the LCD display.
2.
The LCD display will indicate the difference between the stored value
and measured value
3.
Press the REL button to exit the relative mode.
V. 01 – 04/05/2023