in continuous mode until the tar-
get humidity is reached.
Stacking devices
For operation or storage, it is permis-
sible to combine maximum two devic-
es in a stack.
1. Do to this, loosen and fully retract
the handle of the device at the bot-
tom.
2. Place the second device on the
first one. Ensure that the bases of
the second device slot into the re-
cesses in the first one.
Connecting device to electric
power mains
1. Ensure that the voltage of the
power mains corresponds to that
specified in the Technische
Daten/Technical Data.
2. Ensure that the mains socket is
sufficiently protected (see
Technische Daten/Technical Da-
ta).
3. The power socket to which the
device is connected must be
equipped with a RC circuit break-
er. This is particularly important for
operation in humid rooms and on
construction sites.
4. Make sure that the mains socket is
earthed and matches the power
plug of the device.
5. Connect the power plug into the
mains socket.
8 Device operation and
control
Prior to switching on
1. Make sure that the device is not
standing on a wet ground and en-
sure that it is in an upright and
stable position.
2. Make sure that the condensate
can drain off properly.
3. If necessary, record the readings
of the operating hours counter and
the power meter.
NOTICE! Before starting the device
for the first time, after transport
and after prolonged storage, leave
the device in its final position for
approx. 15 minutes before switch-
ing it on.
Switching on device and
continuous operation
in
1. Set the device switch to position
[I].
 The green indicator is lit, in-
dicating that the compressor
is running.
 The device is set to continu-
ous mode and runs until the
automatic defrost function is
triggered (yellow indicator lit).
In continuous mode, conden-
sate is automatically pumped
off.
Pumping off condensate (before
moving device to a different
location)
 The device must not be in defrost
mode (yellow indicator must be
off).
23