A pause can be carried out while pressing on the 'OFF' key.The timer stops. This can be useful
to make a pause, to change a needle, for example.
While pressing again on the foot pedal, we continue where we paused. The timer continues
counting, and the impulses meter too.

5.1.1. Type of Needles

Insulated Ballet needles. For easy penetration, use Ballet needles.The size varies according
to the diameter of the varicosities to be treated.
 - K3i 0.075 mm for very fine varicosities of less than 0.3 mm
 - K6i 0.150 mm for varicosities of more than 0.3 mm

5.1.2. Systematic test before each pulse

5.1.3. Verification of effectiveness

Immediately :
-
Pull the skin well after treatment with both hands to see, using the magnifier headband,
that the varicosity has disappeared;
-
If the pulse is too lateral, the varicosity will reappear;
disappearance in itself is not a sufficient condition (because it is masked by the
edema) for the success of the treatment, but it is a necessary condition.
On D8 for even D15 :
-
Repeat the inspection.
Date 27/03/2014
THERMOCOAGULATION – Viridex
Before sending the pulse, you must find the correct needle
position by pressing on the varicosity with the needle until a
small thread of varicosity disappears, confirming that you
are properly positioned on the varicosity. The gentle
pressure of the needle should make the varicosity
disappear. At this moment, insert the needle very gently
(still superficial) and send the pulse.