C) Selecting a changeover, pulse or dimmer output:
For a changeover output, see figure 4.1.
For a pulse output, see figure 4.2.
For a dimmer output, see figure 4.3.
REMARK: Before changing a setting, you must remove the mains
voltage, because otherwise the processor will not accept the new
settings.
TEST AND USAGE
Connect a bulb to the points marked LOAD.
Connect the mains voltage to the points marked MAINS.
ATTENTION: CERTAIN POINTS OF THE CIRCUIT CARRY
MAINS VOLTAGE NOW.
A) Operation of the local push button
Receiver set for dimmer output:
- Short press: min/max dim position
- Keeping the push button pressed: dims up to the maximum and
back
- Releasing, and pressing again: dims in the other direction
Receiver set for on/off output:
- Pressing: on
- Releasing: stays on
- Pressing: off
- Releasing: stays off
Receiver set for pulse output:
- Pressing: on
- Releasing: off
B) Operation of the remote control:
1) Push buttons 1 through 15:
Receiver set for dimmer output:
- Keeping the button pressed: dims up to the maximum and back
- Releasing: remains in the current dim state
- Pressing again: dims in the same direction