9
10
Flat vehicle fuses
Fault
Leisure area battery not charged
when vehicle is moving (battery vol-
g (
tage does not rise after some time).
t
d
t i
ft
8200510 BA / EN
All manuals and user guides at all-guides.com
Operating Instructions Booster WA 121545
Initial use
The booster is switched on automatically as soon as the vehicle engine is
started.
Check the following before trying to start the first time:
"
Are all the plug connectors secure?
F
Are all the cables connected with the right polarity?
F
Are all the cables secured correctly in the tension clamps?
F
Are the cables adequately secured?
F
Are all the settings correct as per the requirements?
F
- - Correct battery type set ("Batt. Type")
- - Is the power reduction characteristic suitable for the generator
("Power Reduct.")?
- - Is the maximum current appropriate for the fusing (Max. Output")?
Start the engine.
"
Check the booster display:
"
Is a charge mode displayed?
F
Is LED "Error" off?
F
ATTENTION!
Y
If the "Error" LED lights or nothing is displayed, check the cabling and the
settings.
Faults
A flat battery or defective fuse is the cause of most faults in the 12V system.
When it is not possible to rectify a fault based on the following table, please
contact Schaudt customer service (for address, see Page 25).
Possible cause
Incorrect battery type set
y
ti
)
The power reduction characteristic
set, "Power Reduct." C1 to C4, is not
appropriate for the generator.
No D+ signal on the booster.
Too many consumers are switched on. Switch off any consumers not requi-
The device has an excessively high
temperature.
Date: 21.09.2017
Remedy
Set the correct battery type (see Sec-
tion 8.4).
Set the correct characteristic -- refer to
the recommendations in Section 8.4.2.
Consult with the manufacturer of the
base vehicle.
Contact customer service or your dea-
ler as required.
Check whether 12V is applied to boo-
ster input D+ when the vehicle engine
is running.
If not: Check and replace as neces-
sary the 2A fuse.
No D+ signal even when the fuse is in-
tact:
Contact customer service or your dea-
ler as required.
red.
Improve the ventilation; clean dirty
ventilation slots as required.