ADJUSTING THE MICROSWITCHES
DIP 1 CHECKING THE ROTATION DIRECTION OF THE
MOTOR (ON) (POINT C)
DIP 2 TIMING (ON) (POINT D)
OPERATING MICROSWITCH
DIP 3 Pausing time before automatic closing in normal
and pedestrian mode (ON)
DIP 4 Jogging radio receiver (OFF) - automatic (ON)
DIP 5 Single impulse command (K BUTT) jogging (OFF) - automatic
(ON)
DIP 6 Photocells always active (OFF) - Photocells active only on
closure (ON)
DIP 7 Encoder for the K PLUS operators - MUST BE IN OFF
POSITION
DIP 8 Pre-blinking (ON) - Normal blinking (OFF)
DIP 9 Deceleration (ON) - MUST BE IN OFF POSITION
DIP 10 Electronic brake - MUST BE IN OFF POSITION
DIP 11 Gradual start - MUST BE IN OFF POSITION
DIP 12 230V Motor or 120V - MUST BE IN OFF POSITION
LED SIGNALS
DL1 photocells contact (NC)
DL2 stop contact (NC)
DL3 opening limit switch contact (NC)
DL4 closing limit switch contact (NC)
DL5 programming operated
DL6 gate on opening "OPEN" (green)
DL7 gate on closure "CLOSE" (red)
DL8 manual release safety device (NC)
DL9 Disabled
- C -
CHECKING THE ROTATION DIRECTION OF THE
MOTOR
This control is carried out to facilitate the installation of the system or any
possible future control.
1 - After you have ensured the correct positioning of the limit switch
plates (Fig.7), manually move the gate to half open position;
2 - Put DIP 1 in the ON mode => The LED DL5 starts blinking;
3 - Press the PROG button and hold it (the gate now is controlled in a
dead man mode: open, stop close stop open-etc...) => THE RED LED
DL7 "CLOSE" comes on and the gate starts closing (if it does not
close, invert the wires of the motor V and W) until it reaches the limit
switch of the close position (if the gate and motor do not stop, release
the PROG button and invert the position of the cables LSO and LSC
in the J9 connector);
4 - Press the PROG button and hold it => THE GREEN LED DL6
"OPEN" comes on and the gate opens until it reaches the limit
switch for opening position;
5 - On completion of checks and settings of the stroke end
switches, position DIP1 on OFF. The led DL5 will turn off to indicate
exiting the control mode.
NB: The photocells are not active during this control.
- D -
TIMING
NB: DIP7, DIP9, DIP10, DIP11, DIP12 SHALL BE ON MODE OFF!!
The programming can be carried out regardless of the gate position.
1 - Put DIP 2 in the ON mode => the LED DL5 emits short blinkings.
2 - Push the button PROG. => the gate closes and opens automatically
2 seconds after It closed. When the opening cycle Is terminated, It
stops. Wait as long as you want the gate to remain open (excluded
by DIP3 OFF).
3 - Push the button PROG. to command the gate closing (also the pause
time count before the automatic closing stops - max. 5 minutes).
4 - The gate stops as the closing cam is reached.
5 - WHEN THE TIME PROGRAMMING IS COMPLETED, POSITION
DIP 2 ON MODE OFF.
O
PERATION OF THE OPERATING ACCESSORIES
OPENING BUTTON (with timer function)
When the gate is standstill, the button operates the opening mode. If you
push this button when the gate is on closure, It opens again.
TIMER FUNCTION
This function is useful In the rush hours, when vehicle traffic is slow (e.g.
entry/exit of workers, emergencies In residential or parking areas and,
temporary, for removals).
APPLICATIONS
By connecting a switch and/or a daily/weekly timer (in place or in parallel
with the opening button N.O. "COM-OPEN"), it is possible to open the
automation or to keep It open, as long as the switch is on or the timer is
activated.
When the automation is open, all operating functions are inhibited.
If the automatic closing Is started, by releasing the switch or at the time
set before, the automation immediately closes; if not, you need to
operate a command.
CLOSING BUTTON (COM-CLOSE)
When the gate Is standstill, It operates the closing.
JOGGING OPERATION BUTTON (COM-K BUTTON)
If DIP5 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP5 is ON => It opens the gate when this Is closed. If It Is operated
while the gate Is opening, It has no effect. If It Is
operated when the gate is open, it closes the gate and,
If It Is operated while the gate Is closing, It opens the
gate again.
RADIO TRANSMITTER
If DIP4 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP4 is ON => It opens the gate when this is closed. If It Is operated
while the gate Is opening, It has no effect. If It Is
operated when the gate Is open, It closes. If It Is
operated while the gate Is closing, It opens the gate
again.
AUTOMATIC CLOSING FOR COMPLETE OR PEDESTRIAN
OPENING
The pausing time before the automatic closing for both, complete or
pedestrian opening is set during the time programming. In both cases the
maximum pausing time available is 5 minutes . Pause time can be
started or stopped by DIP3 (ON started).
OPERATION AFTER BLACK-OUT
When mains electrical power is restored press the opening button (K,
OPEN, radio).
The gate will open. Let the gate close itself with automatic closure or wait
that the flasher stops blink first to command the closing movement. This
operation is valid to obtain the leaves position readjustment. During this
phase all safety devices are active.
S
AFETY ACCESSORIES OPERATION
PHOTOCELL 1 (COM-PHOT 1))
If DIP 6 is OFF => The gate does not open if there Is an obstacle within
the photocells range of action. During operation,