Herunterladen Diese Seite drucken

Camille Bauer SINEAX TV829 Serie Bedienungsanleitung Seite 49

Hochspannungs-trennverstärker

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SINEAX TV829 Art.-no. 158 320 and 158 338
Specifications (continued)
Isolation
Protection against
electrical shock
For applications with high working voltages, you should ensure there is sufficient spacing
or isolation from neighboring devices and protection against electrical shocks.
Calibrated range selection:
Safe Isolation according to EN 61140 by reinforced
insulation in accordance with EN 61010-1
Working voltages with overvoltage category III and
pollution degree 2:
– up to 1100 V across input, output, and power supply
– up to 300 V across output and power supply
49
49
49
49

Werbung

loading