Fault
Machine axis tracking error
Irrecoverable errors occurred
during communication
Important system components
could not be found
Process crashed. Restart pro-
cess?
Process crashed again. Set to
factory settings and software
version?
11.3. UNLATCH THE EMERGENCY STOP SWITCH
WARNING
Unlatch the emergency stop switch
Serious injuries to the hands.
» Do not unlatch the emergency stop switch until the hazardous situation has been rectified.
ü Rectify the hazardous situation.
1. Twist the emergency stop switch in direction of the arrow and pull it upwards.
» The emergency stop switch is now released.
2. Acknowledge the warning message on the screen.
» The setting bench is now ready for operation.
Possible cause
Axis movement is being ob-
structed by an object.
Defective communication with
the CNC / MCU. Problem-free
operation unavailable.
Update failed or power supply
was interrupted.
Setting Bench or a start com-
ponent has crashed.
Setting Bench or a start com-
ponent has crashed again.
www.hoffmann-group.com
Action
Remove the obstruction, per-
form movement to reference
points.
Contact Hoffmann Group cus-
tomer service
Switch off the Setting Bench, re-
solve potential sources of faults,
switch it on again.
Contact Hoffmann Group cus-
tomer service.
Install update afresh. If neces-
sary, reset to factory settings.
Start the process afresh.
Reset to factory settings.
Contact Hoffmann Group cus-
tomer service.
en
57