The function in the different operating modes is as follows:
Temperature mode
The generators start or stop as soon as "Start" or "Stop" is
pressed on one of the generators. The generators then function
according to their own settings. In other words: When one
of the generators has reached its set temperature, the other
generator will continue to operate until it has also reached
its set temperature. With the exception of the "Start" and
"Stop" buttons, there is therefore no synchronisation of data.
In the event of an alarm, the one generator will therefore not
automatically stop the other generator.
Furthermore, the other functions such as the Thold mode, the ΔT
mode and the Advice function as described in section 7 can be
used as normal on each of the generators.
Time mode
The generators start or stop as soon as "Start" or "Stop" is pressed
on one of the generators. The two generators then function
according to their own settings. In other words: When one of
the generators has reached its set time, the other generator will
continue to operate until it has also reached its set time. With the
exception of the "Start" and "Stop" buttons, there is therefore no
synchronisation of data. In the event of an alarm, the one generator
will therefore not automatically stop the other generator.
Time or Temperature mode
The generators start or stop as soon as "Start" or "Stop" is
pressed on one of the generators. The generators then function
according to their own settings. In other words: When one
of the generators has reached its set time or temperature
(depending on which of the two is reached first), the other
generator will continue to operate until it has also reached its
set time or temperature. With the exception of the "Start" and
"Stop" buttons, there is therefore no synchronisation of data.
In the event of an alarm, the one generator will therefore not
automatically stop the other generator.
Furthermore, the other functions such as the Thold mode, the ΔT
mode and the Advice function as described in section 7 can be
used as normal on each of the generators.
Temperature and speed mode
The generators start or stop as soon as "Start" or "Stop" is
pressed on one of the generators. In this mode, heating data are
synchronised between the two generators. Both generators will
try to heat the workpiece together according to their settings. The
settings have to be made separately on each generator. These
settings are not exchanged between the two generators. The slower
of the two generators will ultimately also reduce the heating speed
of the faster generator. This is effected such that the two generators
reach their set temperatures at more or less the same time.
If a fault occurs here in one of the generators and it stops, the
other generator will also stop heating and go to 0 power.
Schaeffler Technologies
IMPORTANT!
It is important that the generators are all displayed
in the "Settings" mask (mask with the "Start"
button) in order to be able to start them all at the
same time.
All the generators adopt the operating mode
of the generator on which the "Start" button
was pressed. Operating generators together
in different operating modes, e.g. one in time
mode and the other in temperature mode, is not
possible. All generators must therefore be set to
the same operating mode.
The network connection indicator is displayed continuously
on the screen in all operating modes. The indicator is white
as long as the connection between the generators is OK. If the
connection is interrupted, the indicator turns orange. The system
automatically tries to restore the connection. If this takes too
long, heating in "Temp & speed" mode stops. In such cases,
check the network connections, cables, etc. and try again.
A few examples of how the network indicator is displayed on the
screen are illustrated below.