Herunterladen Diese Seite drucken

Schaeffler MF-GENERATOR-3.0 - 10kW Bedienungsanleitung Seite 20

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Press "info"
for further information on the heating process
and the following screen is displayed.
Press "Previous"
to return to the previous screen.
The process runs according to the set value, irrespective of which
of the two screens is displayed.
When one of the set values (temperature or time) is reached, the
process stops. The process stops at the first value reached. The
most recent data from the process are then displayed.
Press "Previous"
to return to the settings screen (start
screen). The heater is now ready for the next heating.
The heating process can be stopped at any time by pressing the
"Stop" button
.
Temperature and speed mode
Determine whether all the settings are as desired (section 7).
Alter the desired temperature "Temp" and/or desired maximum
heating speed "Max. speed", if necessary. Activate the "Hold
temp" and "Log" functions, if desired. The maximum speed
functions well only if the set gradient is realistic in relation to the
maximum power that the generator can output in relation to the
workpiece.
20
NOTE!
The desired temperature and desired power do not have to be set
if an inductor with identification feature is connected. In this case
the generator automatically adopts the settings defined in the
program (1, 2 or 3) for the corresponding inductor.
Press "Start"
. The process starts and the following screen
appears.
An additional dotted line is displayed in the chart. This is the
set gradient and the line along which temperature T1 (red
line) should rise. The generator regulates the power to a level
corresponding to the set gradient.
Press "info"
for further information on the heating process
and the following screen is displayed.
Press "Previous"
to return to the previous screen.
The process runs according to the set value, irrespective of which
of the two screens is displayed.
The exact process routine depends on the "active" functions and
how they are set. For example, the ΔT function.
When the set value is reached, the process stops and the most
recent data from the process are displayed.
Schaeffler Technologies

Werbung

loading