Herunterladen Diese Seite drucken

FILTERMIST FX-Serie Installation Und Wartung Seite 23

Vorschau ausblenden Andere Handbücher für FX-Serie:

Werbung

Suspension Method
4
(FX900/1200)
Any suitable chain with a suitable load capacity may be used
to secure the unit. Please refer to Fig. 5 for unit weights.
I M P O R T A N T !
No less than 4 chains should be used to suspend the
unit. Chain lengths should be as short as possible
and should be spread so that they angle away from
the unit- at least 20 degrees out of vertical.
If using Royal Products suspension kit:
a) Secure suitable lengths of chain to eyebolts on unit casing
using split links provided.
b) Fit eyebolts provided to suitable load bearing area of
ceiling or framework.
c) Secure chains to eyebolts using remaining split links. The
turnbuckle provided should be fitted in one length of chain
and adjusted until the unit is level.
I
M
ODEL
FX300
FX575
FX900
FX1200
Ducting
5
Flexible oil resistant ducting should be used to connect the unit
inlet to the machine cabinet.
All ducting should be kept as short and as straight as possible.
Long runs of ducting can dramatically reduce the airflow of
the unit. "U" bends will also have the same effect, allowing oil
to collect within the bend, thereby restricting the airflow still
further.
NOTE: Only use continuous lengths of liquid-tight
ductwork. Sheetmetal HVAC ductwork could leak and
cause a hazardous condition.
H
U
NLET
OLE
NIT
D
W
IAMETER
EIGHT
6
/
"
32lb
1
2
6
/
"
34lb
1
2
6
/
"
53lb
1
2
8
/
"
64lb
1
2
Oil Drain Tube
6
Connect
/
" I/D hose to the drain tube of the unit. This
3
4
hose should be long enough to reach the machine sump,
machine bed or other collection vessel.
The hose should be free of kinks and bends and the end
must not be submerged or blocked.
MAINTENANCE
For normal machining operations the following
maintenance routines are recommended.
EVERY 1000 HOURS RUNNING TIME
Clean area where top & bottom of case join together
Install new drum pads
Install new seal
Check inlet is clear
EVERY 2000 HOURS RUNNING TIME
Remove drum and clean
Clean area where top & bottom of case join together
Clean drain hole
Install new drum pads and silencer
Change motor AV mounts
Install new seal
Check inlet is clear
For FX300/575 a 22mm thin walled socket should be used
when removing the drum, and should be retightend to 20Nm.
In more arduous conditions e.g. grinding or cast-iron
machining the units should be checked and cleaned on a
more frequent basis according to duty.
Contact Royal Products for details of maintenance plans
Fig. 4
and kits.
CALL TOLL FREE 1-800-645-4174
IMPORTANT - USE ONLY GENUINE ROYAL
FILTERMIST REPLACEMENT PARTS - USE OF
UNAUTHORIZED REPLACEMENT PARTS
WILL INVALIDATE THE WARRANTY.
WARRANTY
Fig. 5
We warrant that within five years from the date of shipment if the Royal
Filtermist unit sold by us is in the possession of the original buyer from an
authorised distributor, we will replace or repair, at our option, free of charge,
any part or parts, other than the electric motor and consumable items, ie:
Needle mat pads and silencers, "O" ring seals, flexible ducting, etc. which upon
examination we find to be defective in workmanship or material, provided that,
on our request, the product or parts thereof are returned to our plant, along
with satisfactory documentation that the Royal Filtermist unit has been properly
used and maintained.
The electric motors are covered by a separate one year warranty issued by the
manufacturer and can usually be rebuilt at a local repair station.
This warranty is in lieu of all other express or implied warranties (including
without limitation and warranty of merchantability or fitness for a particular
purpose). In no event shall we be liable for any special indirect or consequential
damages (including but not limited to, lost profits or other damages from loss
of production) caused by defective material, or by unsatisfactory performance
of the product, or by any other breach of contract by us.
NOTES

Werbung

loading

Diese Anleitung auch für:

Fx4002Fx5002Fx6002Fx7002