Einhebel-küchenmischer 260 für offene warmwasserbereiter

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
Water escaping in area of swivel
spout
Water escaping at the threaded base - O-ring at the connection hose de-
Water escaping bels ow handle
4
English
max. 1 MPa
0,1 -0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 5 l/min
max. 70°C / 4 min
Cause
- Spray former calcified, dirty
- Filter at the isolation valves soils.
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
fective.
- connection hoses not completely
screwed into basic body
- Cartridge defective
Assembly see page 32
Symbol description
Do not use silicone containing acetic acid!
Operation (see page 36)
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
• When the storage tank is being heated,
the spout will drip.
Maintenance (see page 37)
• The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• When changing the spray former, it is
imperative to use one made for this type
of mixer.
Dimensions
(see page 31)
Spare parts
(see page 38)
Cleaning
(see page 39)
Test certificate
(see page 40)
Remedy
- Clean spray former, exchanging if
necessary
- Clean the filter / exchange filter
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange cartridge