5.3. SE-1 sensors (Niva-3)
A. Declaration of conformity
Bleu Electrique SAS (FR47403521693) declares that product RNS-1, RNS-2
and NIVA 3 Module is compliant with the safety and electromagnetic compati-
bility requirements of European directives E.M.C (2014/30/UE), Low voltage
(2014/35/UE), RoHS (2011/65/UE), WEEE (2002/96/CE) and REACH (1907/2006).
Date of sale: . . . . . . . . . . . . . . . . . . . . . . . Batch N°: . . . . . . . . . . . . . . . . . . . . . . . . . . .
RNS-1, RNS-2 and NIVA 3 Module
The 3 SE-3 sensors are placed in the skimmer, separately from
each other. We recommend installing them in a channel or a
PVC pipe to isolate them from the wall and keep them separate.
The sensors must be fixed at the required height to prevent them
from moving and avoid any pull on their wire. The sensor wires
must be guided so that they do not tangle.
A. High level (to connect to terminal 3)
B. Low level (to connect to terminal 4)
C. Ref. level (to connect to terminal M)
If the water level is above the high level (A), filtration is autho-
rised and automatic filling is stopped.
If the water level is below the low level (B), the device stops
filtration (pump prohibition) and activates filling until the high
level is reached (A), or stops after 3 hours (see Fault section)