FIITING AND WIRING INSTRUCTIONS
Important recommendations
Before installing the device or performing any mainte-
nance, make sure all the safety instructions listed below,
will be fully met:
• The installation must be in accordance with the electri-
cal standards and regulations in force in your country
and by qualified personnel.
• Precautions must be taken to avoid the back-flow of
gases into the room from the open flue or other fu-
el-burning appliances.
• Ensure the shutter arm is located into the shutter slot
when the External grill is fitted. Finally check for cor-
rect running and shutter operation.
• If the fan operates as an extractor in a room with a
boiler or any other type of appliance requiring air for
combustion check that air replacement inlets are suf-
ficiently sized.
• Ensure that the values of voltage and frequency of main
supply are compatible with those indicated on the rat-
ing plate of the appliance.
• The electrical installation shall include an isolating
switch that has a contact clearance distance of at least
3 mm.
• Please ensure that a suitable isolator switch is provid-
ed in the electrical circuit. The HV-Series fans are of
Class II (double Electrical Insulation), and therefore do
not need to be connected to earth.
• The device is designed for use in places where the am-
bient temperatures does not exceed +40ºC.
• This appliance can be used by children aged
from 8 years and above and persons with re-
duced physical, sensory or mental capabili-
ties or lack of experience and knowledge if
they have been given supervision or instruc-
tion concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be
made by children without supervision.
• Regulate and clean the appliance or perform user
maintenance.
• The installer shall provide access to the fan to facilitate
future maintenance, and ensure it is properly secured
and installed.
• Motors fitted to models HV-230N and HV-300N include
a thermal protector with automatic reset.
• Fans are only intended for air-conditioned environ-
ments.
10
• Do not use these extractors for potentially explosive or
corrosive environments.
• Check perfect condition and unpacking operation as
any manufacturing defect that is covered by this war-
ranty S&P.
• The HV range is designed to the be installed in either
glass windows and walls.
MOUNTING ON GLASS WINDOWS OR WALL
thickness between 3 and 25 mm
Cut a hole following the dimensions indicated on fig. A.
It is recommended that this should be a minimum of
1500mm from ground level.
Dismantle the HV-fan in accordance with the following
instructions:
Fig. 1
Loosen the retaining screw (b) fixing the internal
front cover (a).
Fig. 2. Remove the internal front cover (a) by pressing
the knobs (c).
Fig. 3
Unscrew the 3 bolts (d) fixing the external grille
(e) and separate from the support plate (f).
lnstall the HV-fan as follows:
Fig. 4
Pull the external grille (e) towards you and
turn the rubber mounting (g) on the screws (h),
towards he inner side of the grille.
Fig. 5
From the outside, place the external grille (e)
over the hole in the glass. From the inside, turn
and push the rubber mountings (g) until they are
located against the glass keeping the external
grille (e) in its correct position.
Fig. 6
Mount the support plate (f) to the screws (h) of
the external grille (e) and tighten the bolts (d) to
suit the thickness of the glass:
- Glass thickness 3-14 mm: Fig. 6a
- Panel thickness 14-25 mm: Fig. 6
Tighten the screws taking care not to flatten the
rubber joints between the support plate and the
external grille.
Ensure that the glass is not in contact with the
plastic frame.
Fig. 7
Make the necessary hole in the gland (i), and feed
the electrical cables through the clamp (p) and
correct them in the terminal box (k).
Fig. 8
Mount the internal cover (a) by slotting the retan-
gular openings (1) on the top of the cover (a) into
the receivers (m) of the support plate (f) until the
two knobs (c) are correctly positioned.
Fig. 9
Tighten the locking screw (b).