6.3 Replacing of the illuminant
WARNING! The LED-illuminant must be replaced by a competent
person only. If the LED-illuminant is damaged, please contact a qualified
professional. Illuminants and the replacing of illuminants are not included
in guarantee.
7. Trouble shooting
POSSIBLE CAUSE
T
1. The plug of the appliance is not
connected to the socket.
2. The plug has become loose.
3. The socket is not supplied with
energy.
4. The fuse is switched off.
5. The voltage is too low.
L
1. Ventilation damper blocked.
2. Motor mounting defective.
1. Motor defective.
1. One-way valve is leaky.
1. Motor not properly fixed.
2. Hood not properly fixed.
MALFUNCTION
HE APPLIANCE DOES NOT WORK AT ALL
IGHT IS ON BUT MOTOR DOES NOT WORK
A
BNORMAL MOTOR
S
MEAR OF OIL
A
PPLIANCE VIBRATES
MEASURE
:
1. Connect the appliance to the mains
properly.
2. Check the plug.
3. Check the corresponding socket by
connecting it with another appliance.
4. Check the fuse box.
5. Compare the data on the model plate
with the data of your energy supplier.
1. Remove blockage.
2. Replace motor.
-
:
SMELLS
1. Replace motor.
:
1. Seal the valve.
:
1. Fix motor properly.
2. Fix hood properly.
: