Watts BT-M6Z02-RF 230V/24V Bedienungsanleitung Seite 9

Regelverteiler funkline

Werbung

Erase master link:
Use this function to erase master code.
In 'Run mode', press (►) key during 10 seconds to enter in RF initialization mode for master, then the red
LEDS of zone are blinking;
Then user has to press the 2 keys (◄) and (ok) during 5 seconds; (system should go out of master RF
initialization mode).
Erase thermostat function:
With this function you could remove one or several thermostats of your installation.
Once on the "RF init" menu, choose the zone which must be removed with the blinking cursor and press 5
seconds in the same time the (◄) or (►) keys. Then the LED(s) of the zone(s) which worked with the
thermostat will be removed.
Factory settings function:
Use this function to erase all configurations and download the factory settings.
In 'Run mode', press in the same time during 5 seconds the 2 keys (◄) and (►). Release the keys only when
all LED are blank. Then the product has been resetted.
10.
SYSTEM CONFIGURATION
Relay pump is activated when there is
one zone activated at least.
(If BT-M6Z02 RF is master, relay pump
is activated if there is one zone
ON
activated
network.
If BT-M6Z02 RF is slave, relay pump is
activated if there one zone of slave
network activated at least.)
OFF
Relay pump is not used
If BT-M6Z02 RF is slave, relay pump is activated on both the master and the slave if there one zone of slave
network activated at least.
Antenna
Switch 1
at
least
on
the
global
Switch 2
Switch 3
Outputs are
There is a pump
normally opened
Outputs are
There is no pump
normally closed
9
ON
OFF
ON
OFF
Switch 4
Not used
exercise.
Not used
exercise