Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking
water!
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Residue
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
Assembly (see page 14)
English
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 16)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance (see page 18)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 20)
Flow diagram (see page 20)
free flow
Spare parts (see page 21 )
XXX = Colors
000 = Chrome Plated
670 = Matt Black
+
Special accessories (see page 21 )
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough)#13597XXX
Cleaning (see page 24)
Operation (see page 17)
Test certificate (see page 24)
Remedy
- Exchange cartridge
- Exchange cartridge
- Clean converter / grease O-rings
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange cartridge