AUDIO ADJUSTING
The audio levels are trimmed in factory, so they don't need to be changed in most installations.
If it is necessary to change them, use a screwdriver on the suitable adjusting points.
DOOR ELECTRIC LOCK MANAGEMENT
The door units have two terminals for managing the capacitance discharge and hold of the door electric lock
(SE-, SE+). The electric lock is operated in the following cases:
Whenever the hall button is pressed (terminals PA, CT).
When is received a pedestrian crossing door lock release command coming from an apartment station,
according to the confi guration of the dip-switch AUX used to select operating mode "free" or "privacy"
(see "Confi guration" section).
The electric lock activation time can be programmed by rotary switch (30 seconds max.).
TECHNICAL SPECIFICATIONS
Power voltage (LINE):
Stand-by consumption:
Max. consumption:
Lock output SE+ and SE-:
Working temperature range:
Reference standards:
DS1083-124
36 – 48Vdc
45mA max
250mA max
22 – 24Vdc max 200mA
-10°C ÷ + 50°C
EN 61000-6-3, EN 61000-6-1